NOTE
• For open collector output, the signal may become unstable if the input resistance of the connected device is large and the
device may detect the signal incorrectly. In this case, adding a pull-up resistor as shown below will improve the
phenomenon. Select a pull-up resistor in consideration of the input current of the connected device so that the open
collector output current will not exceed the output permissible load current.
Inverter
FR-A8TP
Pull-up resistor
FPA5/FPB5/FPZ5
SD
Power supply
-
+
Connected device
ENCODER PULSE DIVIDING OUTPUT
8
67