Vector control terminal block
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

 Motor used and switch setting
Motor
Mitsubishi Electric standard motor with
encoder
Mitsubishi Electric high-efficiency motor with
encoder
Mitsubishi Electric constant-torque motor with
encoder
Mitsubishi Electric high-performance energy-
saving motor with encoder
Vector control dedicated motor
Other manufacturer's motor with encoder
*1
Set according to the motor (encoder) to be used.
*2
Prepare an encoder's power supply (5 V/12 V/15 V) according to the encoder to be used. Use terminal PG24 for the 24 V encoder's
power supply.
*3
When the encoder output is the differential line driver type, only 5 V can be input.
NOTE
• When power is not supplied to the control circuit of the inverter, also turn OFF the power supply to the encoder. Otherwise,
the plug-in option may be damaged.
30
WIRING
Encoder specification
selection switch (SW3)
SF-JR
Differential
SF-HR
Differential
*1
Others
SF-JRCA
Differential
SF-HRCA
Differential
*1
Others
SF-PR-SC
Complementary
SF-V5RU
Complementary
SF-THY
Complementary
*1
Terminating resistor
selection switch (SW1)
ON
5 V
ON
5 V
*1
*1*3
ON
5 V
ON
5 V
*1
*1*3
OFF
12 to 24 V
OFF
12 to 24 V
OFF
12 to 24 V
*1
*1*3
Power supply
*2
specification