NetFn
Command
Request Data:
Byte
1
Response Data:
Byte
1
2

2.18 Get Fault LED Mask

This is the command to get fault led mask.
Linux command:
$ ipmitool raw 0x3c 0x13
Description:
NetFn
Command
Request Data:
Byte
NONE
Response Data:
0x3c
0x12
Data field
Mask Byte
0xFF: Any of below errors will turn on fault led 0x00: Mask
all of errors
The bit description is below:
[7] – PSU Error Mask
[6] – Undetermined Error Mask
[5] – CPU Fault Mask
[4] – Overtemp Mask
[3] – Hightemp Mask
[2] – DIMM Error Mask
[1] – FAN Error Mask
[0] – Sensor Error Mask
Data field
Completion Code
Mask – The mask is set
0x3c
0x13
Data field
NONE