Duct Assembly
1
2
3
Pump Ass'y
① Remove a screw from the duct clamp and 2 bolts
from the rear cabinet.
② Unfasten the bellows clamp, inlet hose and hose
clamp, pressure sensor, 3 housings, 2 screws
connected to the grounding wires, and the drain
valve clamp of condensed water.
③ Repair the duct assembly.
At this time, make sure that the pipes are not
damaged or deformed.
① Remove 4 pump harnesses and 4 clamps of each
hose.
(Make sure that all remaining water is completely
removed prior to starting work.)
② Incline the product and remove 3 pump screws on
the floor.
Push the pump hook to the back of the product
and remove it.