5.3 Aligning the travel indica-
tion scale
The travel indication scale has two opposed
scales. Which scale is to be used depends
on the valve version. In the delivered state,
the scale alignment applies to globe valves
and three-way diverting valves. The align-
ment needs to be changed when a three-
way mixing valve is used.
Driving pin in position 0,
location of scale with globe or three-way di-
verting valves (delivered state)
Fig. 5-2: Travel indication scale
Globe and three-way diverting valves:
the driving pin is in position 0 (delivered
state).
Three-way mixing valve:
change the alignment of the scale.
Î Carefully open the front cover.
5-2
Hole for driving pin
with three-way mixing
valve
NOTICE
!
The display does not work due to an inter-
rupted cable connection.
Î Only open the front housing cover to
perform actions described in these in-
structions.
Î Do not disconnect the connecting cable
between the electric actuator and hous-
ing cover.
Tip
We recommend screwing the bottom screws
of the open housing front cover into the top
holes of the housing.
Î Remove scale, turn it and replace it so
that the pin is positioned over the appro-
priate hole (6, 12 or 15) corresponding
to the rated travel (6, 1 or 15 mm travel).
Î Close front cover.

5.4 Mounting the actuator

The electric actuator with process controller
is mounted either directly onto the valve or
using a yoke depending on the valve version
used (see Fig. 5-3).
NOTICE
!
Risk of actuator damage due to excessively
high tightening torques.
Î Observe the tightening torque.