DTC P0615: Starter Relay Circuit Malfunction

NOTE
• Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after several starting attempts, or with the engine running.
• Computer operating voltage: 9 V < operating voltage < 16 V.
• Battery voltage that is too low can cause the Injection warning light (gravity 1 warning light) to come
on thereby causing other faults to appear.
• Use service wire for all operations on the ECM connectors.
Wiring Diagram
For wiring circuit and connector number, refer to "A-5 Engine and A/C Control System Circuit Diagram (DSL): in
Section 9A".
Detecting Condition
Displaying on SUZUKI scan tool
1.DEF
Troubleshooting
Check continuity and make sure there is no interference resistance on the following connection:
• Between "E82-23" wire of junction block connector and "E66-11" terminal of ECM connector
Repair if necessary.
• Check the condition of "IG COIL" fuse located on the junction block assembly.
Check the condition of the "FI" fuse located on a fuse box No.2.
Repair if necessary.
• If the fault does not reappear, start the engine and wait 1 min.
Carry out a road test and check the system faults.
If there are no faults, fault finding is complete.
If the fault is still present, substitute a known-good ECM and recheck.
Engine General Information and Diagnosis:
Detecting condition
Voltage outside permitted range of values
1A-67
S5JB0B1104124