3.
Wrapping the pipe with tape.
Wrap the pipe from the bottom of the outdoor unit to the top of the pipe where it enters the
wall.
Fix the wrapped pipe on the wall with clamps.
CAUTION
Do not wrap the pipe too tightly; otherwise the insulation effect will be reduced.
Make sure the drain hose is separated from the refrigerant pipe
Seal the wall penetration to prevent wind and rain ingress.
3.14. Connection to the Wiring Terminal
WARNING
All electrical work must be carried out by a licensed electrician.
a.
Single-Core Wire
1.
Strip 25mm of the insulating layer at the end of the wire with a wire stripper.
2.
Loosen the screw on the wiring board of the air conditioning unit.
3.
Use pliers to shape the end of the wire to a circle matching the size of the screw.
4. Insert the screw through the wire and then fix it to the wiring board.
20
Figure 19: Insulation for the Refrigerant Pipe
LENNOX MULTI SPLIT INVERTER
Slim Line Ducted Indoor Unit
13 23 50
|
lennoxaus.com.au