Alarm
Name: TBbeRst15Min (3408)
Type: configurationAlarm (11)
Probable cause: T_BBE_RST_15MIN (1237)
Name: TBbeRst1Day (3409)
Type: configurationAlarm (11)
Probable cause: T_BBE_RST_1DAY (1238)
Name: TBerPostFec15Min (3410)
Type: configurationAlarm (11)
Probable cause: T_BERPOSTFEC_15MIN
(1239)
Name: TBerPostFec1Day (3411)
Type: configurationAlarm (11)
Probable cause: T_BERPOSTFEC_1DAY
(1240)
Name: TBerPreFec15Min (3412)
Type: configurationAlarm (11)
Probable cause: T_BERPREFEC_15MIN
(1241)
Name: TBerPreFec1Day (3413)
Type: configurationAlarm (11)
Probable cause: T_BERPREFEC_1DAY (1242)
Name: TBIAESOtu15Min (3394)
Type: configurationAlarm (11)
Probable cause: T_BIAES_OTU_15MIN (1223)
Name: TBIAESOtu1Day (3395)
Type: configurationAlarm (11)
Probable cause: T_BIAES_OTU_1DAY (1224)
Name: TCv15Min (3414)
Type: configurationAlarm (11)
Probable cause: T_CV_15MIN (1243)
Name: TCv1Day (3415)
Type: configurationAlarm (11)
Probable cause: T_CV_1DAY (1244)
Name: TCvPcs15Min (3416)
Type: configurationAlarm (11)
Probable cause: T_CV_PCS_15MIN (1245)
(22 of 37)
Alcatel-Lucent 5620 Service Aware Manager, Release 9.0 R4
3HE 06513 AAAD TQZZA Edition 01
Attributes
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
September 2011
Optical Alarm Reference
2 — 1830 PSS alarms
Description
The alarm is raised when the BBE-RS
15-minute threshold is crossed.
The alarm is raised when the BBE-RS
one-day threshold is crossed.
The alarm is raised when the
post-FEC 15-minute BER threshold is
crossed.
The alarm is raised when the
post-FEC one-day BER threshold is
crossed.
The alarm is raised when the pre-FEC
15-minute BER threshold is crossed.
The alarm is raised when the pre-FEC
one-day BER threshold is crossed.
The alarm is raised when the
BIAES-OTU 15-minute threshold is
crossed.
The alarm is raised when the
BIAES-OTU one-day threshold is
crossed.
The alarm is raised when the CV
15-minute threshold is crossed.
The alarm is raised when the CV
one-day threshold is crossed.
The alarm is raised when the CV-PCS
15-minute threshold is crossed.
2-23