Alarm
Name: InterCardCommsFailure (2036)
Type: equipmentAlarm (3)
Probable cause: ContCom (1020)
Name: InterShelfLossofCommunication
(2037)
Type: configurationAlarm (11)
Probable cause: ShelfContCom (1021)
Name: IntTempHigh (3360)
Type: equipmentAlarm (3)
Probable cause: IntTempHigh (1095)
Name: IntTempLow (3361)
Type: equipmentAlarm (3)
Probable cause: IntTempLow (1096)
Name: IntTempOpt (3362)
Type: equipmentAlarm (3)
Probable cause: IntTempOpt (1047)
Name: InvalidEgress (3363)
Type: configurationAlarm (11)
Probable cause: InvalidEgress (1193)
Name: InvalidThreshold (2038)
Type: configurationAlarm (11)
Probable cause: InvalidThreshold (1022)
Name: InvalidThresholdOms (3364)
Type: configurationAlarm (11)
Probable cause: InvalidThresholdOms (1194)
Name: InvalidThresholdOts (3365)
Type: configurationAlarm (11)
Probable cause: InvalidThresholdOts (1195)
Name: LaserBackFacetOptPwrTca (3366)
Type: configurationAlarm (11)
Probable cause: LaserBackFacetOptPwrTca
(1196)
Name: LaserCoolingCurTca (3367)
Type: configurationAlarm (11)
Probable cause: LaserCoolingCurTca (1197)
(12 of 37)
Alcatel-Lucent 5620 Service Aware Manager, Release 9.0 R4
3HE 06513 AAAD TQZZA Edition 01
Attributes
Severity: Critical
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Critical
Object Type (class): Shelf
Domain: equipment
Implicitly cleared (self-clearing): No
Severity: Minor
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Minor
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Minor
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
September 2011
Optical Alarm Reference
2 — 1830 PSS alarms
Description
The alarm is raised when the card
fails to communicate.
The alarm is raised when control
card redundancy is compromised.
The alarm is raised when a card
reports an over-temperature
condition.
The alarm is raised when a card
reports an under-temperature
condition.
The alarm is raised when an optical
module reports an over-temperature
condition.
The alarm is raised when an egress
port is invalid or undefined.
The alarm is raised due to Invalid
Threshold.
The alarm is raised when an OMS
threshold is invalid.
The alarm is raised when an OTS
threshold is invalid.
The alarm is raised when the laser
back-facet optical power crosses a
threshold.
The alarm is raised when the laser
cooling current crosses a threshold.
2-13