Alarm
Name: LossofSignal (2044)
Type: communicationsAlarm (4)
Probable cause: LOS (1018)
Name: LossofSynchronization (2045)
Type: communicationAlarm (96)
Probable cause: FeLanLss (1028)
Name: LossTooHigh (3373)
Type: configurationAlarm (11)
Probable cause: OprLossHigh (1044)
Name: LossTooLow (2042)
Type: configurationAlarm (11)
Probable cause: OprLossLow (1027)
Name: LostBothClks (2046)
Type: equipmentAlarm (3)
Probable cause: SyncSysOos (1029)
Name: LostPri (2047)
Type: equipmentAlarm (3)
Probable cause: Sync (1030)
Name: LostSec (2048)
Type: equipmentAlarm (3)
Probable cause: Sync (1030)
Name:
ManualProtectionSwitchToProtection (2049)
Type: communicationsAlarm (4)
Probable cause: ManWKSWPR (1031)
Name: ManualProtectionSwitchToWorking
(2050)
Type: communicationsAlarm (4)
Probable cause: ManWKSWbk (1032)
Name: MismatchFiber (3374)
Type: configurationAlarm (11)
Probable cause: MismatchFiber (1203)
Name: MissingWaveKeyRaised (3375)
Type: communicationsAlarm (4)
Probable cause: LosOut (1204)
(14 of 37)
Alcatel-Lucent 5620 Service Aware Manager, Release 9.0 R4
3HE 06513 AAAD TQZZA Edition 01
Attributes
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Info
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Critical
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Minor
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Minor
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Info
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Info
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
September 2011
Optical Alarm Reference
2 — 1830 PSS alarms
Description
The alarm is raised when the loss of
signal occurs.
The alarm is raised when a far-end
system detects a loss of
synchronization.
The alarm is raised when the optical
loss is above the operational range.
The alarm is raised when the optical
loss is below the operational range.
The alarm is raised due to using of
local oscilator for system time..
The alarm is raised due to loss of
primary line.
The alarm is raised due to loss of
secondary line.
The alarm is raised when a manual
APS switch to the protection channel
occurs.
The alarm is raised when a manual
APS switch to the working channel
occurs.
The alarm is raised when a
mismatched fiber connection is
detected.
The alarm is raised when fiber link
gets cut/disconnected.