Alcatel-Lucent 5620 Manual page 28

Service aware manager
Hide thumbs Also See for 5620:
Table of Contents

Advertisement

2 — 1830 PSS alarms
Alarm
Name: ApsSwitchedToWork (1977)
Type: communicationsAlarm (4)
Probable cause: WkSwBk (962)
Name:
AutLaserOffDuetoUpstreamCondition (1978)
Type: communicationsAlarm (4)
Probable cause: UpstreamFault (963)
Name:
AutomaticProtectionSwitchToProtection
(1979)
Type: communicationsAlarm (4)
Probable cause: WKSWPR (964)
Name: B1SignalDegrade (1980)
Type: communicationsAlarm (4)
Probable cause: B1Sd (965)
Name: BackplaneBatteryOff (1981)
Type: equipmentAlarm (3)
Probable cause: Pwr (966)
Name: BatteryOff (1982)
Type: equipmentAlarm (3)
Probable cause: Pwr (966)
Name: BatteryPowerAtBackPlaneOff (1983)
Type: equipmentAlarm (3)
Probable cause:
BatteryPowerAtBackPlaneOff (967)
Name: BoardEqpt (3338)
Type: equipmentAlarm (3)
Probable cause: BoardEqpt (1171)
Name: BothTimingModulesFailed (1984)
Type: configurationAlarm (11)
Probable cause: SyncClkFail (968)
Name: CardAbnormalCondition (1985)
Type: communicationsAlarm (4)
Probable cause: cardMan (969)
Name: CardDegrade (1987)
Type: equipmentAlarm (3)
Probable cause: EqptDgr (971)
(3 of 37)
2-4
Attributes
Severity: Info
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Info
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Info
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Critical
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Critical
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Critical
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Critical
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Critical
Object Type (class): Shelf
Domain: equipment
Implicitly cleared (self-clearing): No
Severity: Info
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Minor
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
September 2011
Alcatel-Lucent 5620 Service Aware Manager, Release 9.0 R4
Optical Alarm Reference
Description
The alarm is raised on Automatic
switch to working.
The alarm is raised when a laser
shuts off automatically in response
to an upstream fault condition.
The alarm is raised when an
automatic APS switch to the
protection channel occurs.
The alarm is raised due to B1 signal
degrade.
The alarm is raised due to battery
power at backplane voltage low.
The alarm is raised due to battery
off.
The alarm is raised when battery
power is off at backplane.
The alarm is raised when a card fails
to initialize.
The alarm is raised due system
timing synchronization both units
failed.
The alarm is raised when port/Card
is in maintainence due to abnormal
condition.
The alarm is raised when the card is
degraded.
3HE 06513 AAAD TQZZA Edition 01