Alcatel-Lucent 5620 Manual page 40

Service aware manager
Hide thumbs Also See for 5620:
Table of Contents

Advertisement

2 — 1830 PSS alarms
Alarm
Name: MixedPFUsed (3376)
Type: configurationAlarm (11)
Probable cause: MixedPFUsed (1205)
Name: ModulatorOutputPowerOutOfRange
(2051)
Type: communicationsAlarm (4)
Probable cause: ModOutOfRange (1033)
Name: MonitorFailure (2052)
Type: equipmentAlarm (3)
Probable cause: Mismatch (1034)
Name: Msim (3377)
Type: configurationAlarm (11)
Probable cause: Msim (1206)
Name: OaPumpBiasCurrHigh (2061)
Type: equipmentAlarm (3)
Probable cause: OaPumpBiasCurrHigh
(1042)
Name: OaPumpTempHigh (2062)
Type: equipmentAlarm (3)
Probable cause: OaPumpTempHigh (1043)
Name: OduAis (3379)
Type: configurationAlarm (11)
Probable cause: OduAis (1208)
Name: OduAisEgress (3380)
Type: configurationAlarm (11)
Probable cause: OduAisEgress (1209)
Name: ODUBackwardDefectIndication
(2053)
Type: communicationsAlarm (4)
Probable cause: BDI (1035)
Name: ODUEgressLocked (2054)
Type: communicationsAlarm (4)
Probable cause: Locked (1036)
Name: ODUEgressSignalDegrade (2055)
Type: communicationsAlarm (4)
Probable cause: SgnlDegrade (1037)
(15 of 37)
2-16
Attributes
Severity: Critical
Object Type (class): Shelf
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Minor
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Info
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
September 2011
Alcatel-Lucent 5620 Service Aware Manager, Release 9.0 R4
Optical Alarm Reference
Description
The alarm is raised when mixed types
of power filters are in use.
The alarm is raised on Modulator
Output Power OutOfRange.
The alarm is raised due to card
degrade.
The alarm is raised when a multiplex
structure identifier mismatch is
detected.
The alarm is raised due to optical
amplifier pum laser bias current
high.
The alarm is raised due to optical
amplifier pump laser temperature
high.
The alarm is raised when an ODU
reports an AIS.
The alarm is raised when an ODU
reports an egress AIS.
The alarm is raised when a BDI is
received.
The alarm is raised when an ODU is
locked.
The alarm is raised when signal
degradation is detected.
3HE 06513 AAAD TQZZA Edition 01

Advertisement

Table of Contents
loading

This manual is also suitable for:

5620 sam5650 cpam

Table of Contents