2 — 1830 PSS alarms
Alarm
Name: PwrMaxGain (2081)
Type: configurationAlarm (11)
Probable cause: PwrMaxGain (1062)
Name: PwrTiltSusp (3389)
Type: configurationAlarm (11)
Probable cause: PwrTiltSusp (1218)
Name: PwrUnbalance (3390)
Type: configurationAlarm (11)
Probable cause: PwrUnbalance (1219)
Name: PwrUnbalanceOms (3391)
Type: configurationAlarm (11)
Probable cause: PwrUnbalanceOms (1220)
Name: RamanSupAlarm (2082)
Type: configurationAlarm (11)
Probable cause: RAMANSUP (1063)
Name: RcvrOptProg (2083)
Type: equipmentAlarm (3)
Probable cause: RcvrOptProg (1060)
Name: RemoteClientLocalFault (2084)
Type: communicationsAlarm (4)
Probable cause: LfiEgr (1064)
Name: RemoteFault (2085)
Type: communicationsAlarm (4)
Probable cause: LanRfi (1065)
Name: ReplUnitMissMOD (3392)
Type: configurationAlarm (11)
Probable cause: ReplUnitMissMOD (1221)
Name: SfpEOLAlarm (2087)
Type: communicationsAlarm (4)
Probable cause: sfpEOL (1067)
Name: SfpTempOOR (2088)
Type: communicationsAlarm (4)
Probable cause: SfpTempOOR (1068)
(19 of 37)
2-20
Attributes
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Major
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Minor
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Info
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Info
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
September 2011
Alcatel-Lucent 5620 Service Aware Manager, Release 9.0 R4
Optical Alarm Reference
Description
The alarm is raised on Gain
Adjustment Exceeded Max Value.
The alarm is raised when amplifier
gain tilt adjustments are suspended.
The alarm is raised when a general
power imbalance is detected.
The alarm is raised when an OMS
power imbalance is detected.
The alarm is raised due to Raman
Suppress - Line
The alarm is raised due to receiver
optimization in progress.
The alarm is raised when a remote
client detects a local fault.
The alarm is raised when a remote
fault is detected.
The alarm is raised when a pluggable
module is missing.
The alarm is raised on SFP or XFP
Laser end of life.
SFP or XFP laser temperature out of
range