Installation and connection

The appliance must be installed in
accordance with all electrical regulations.
Electrical installation
This appliance must be earthed and the
manufacturer and the seller do not accept
responsibility for any damage due to
incorrect installation or electrical connection.
This appliance should not be connected
through an earth leakage system.
Refer to S.A.N.S.10142
Support the oven in front of the aperture and
make the electrical connection before
installing. This will ensure enough cable
length for subsequent servicing.
Connection to the power supply
The connection must be carried out by a
licensed electrician, who will ensure that the
oven is correctly connected and safely
earthed. The rated current is printed on the
serial number label attached to the oven side
trim.
The appliance must be connected to the
mains through a double pole isolating switch
which has a minimum clearance between the
contacts of 3 mm. in both poles.
A means for disconnection must be provided
in the fixed wiring.
DANGER: The appliance must
be connected to the mains supply
only by authorised and qualified
persons. The appliances warranty
period starts only after correct
installation. The manufacturer
shall not be held responsible for
damages arising from procedures
carried out by unauthorised
persons.
DANGER: Risk of electric
shock, short circuit or fire by
damage of the mains lead! The
mains lead must not be clamped,
bent or trapped or come into
contact with hot parts of the oven.
If the mains lead is damaged, it
must be replaced by a qualified
electrician.
Page 11
DANGER: Risk of electric
shock! Before starting any work on
the electrical installation, please
disconnect the appliance from the
mains supply.
Connecting the sprague to the oven
WARNING! ELECTRICAL
CONNECTION MUST ONLY BE
DONE BY A QUALIFIED
ELECTRICIAN!
Purchase a standard plastic/metal saddle
type bracket, capable of going around the 20
mm diameter sprague and with a hole pitch
of 38 mm (Plastic) 45 mm (Metal), from your
local hardware and 2 off 4.2 mm x 12 mm
self tapping screws.
1
Feed the cables through the Sprague and
connect to the mains terminal block of the
appliance.
2
Place the plastic/metal saddle around the
sprague and fasten via the 2 self tapping screws
onto the factory pre punched holes adjacent to
the mains terminal block of the appliance.