Omron F3SG-SR/PG Manual page 36

Safety light curtain/safety multi-light beam
Table of Contents

Advertisement

Auto Reset Mode with Wired Synchronization and EDM Unused
[Wiring Example]
F39-JG C-L
Function
EDM
Interlock
Operating Range Selection
Non-Muting system
External Test not used
Optical Synchronization
Timing chart
Beam state: Unblocked
Blocked
OSSD
Note: For the functional earth connection, refer to page 35.
F39-JG C-D
EDM Disabled (factory default setting)
Auto Reset (factory default setting)
Long (factory default setting) *7
Perform wiring according to the wiring diagram.
Connect the TEST line of the emitter to 0V/24V of the emitter.
Connect the COM(+) and COM(-) line of the emitter and receiver with each other.
*1. Reverse the polarity of the power supply when using in the NPN system. Select a safety
controller of PNP or NPN type according to the system of your application.
*2. If External Test is used, refer to the User's Manual.
*3. Connect the line to 24V/0V (brown) of the receiver via a lockout reset switch (NC contact) if
Lockout Reset is used.
*4. Refer to page 44 for more information.
*5. The safety controller and the F3SG-SR must share the power supply or be connected to the
common terminal of the power supply.
*6. This is the case for a PELV circuit.
*7. The Intelligent Tap is needed to set the Short mode. Set the function with the DIP Switches on
the Intelligent Tap or the SD Manager 3, restore the settings to the F3SG-SR, and perform
wiring according to the wiring diagram.
Intelligent Tap
Not needed
Wiring for NPN * 1
* 6
IN1
IN2
Safety controller
* 4 * 5
Setting
F3SG-SR/PG
24 VDC
24 VDC
36