Omron F3SG-SR/PG Manual page 14

Safety light curtain/safety multi-light beam
Table of Contents

Advertisement

Muting Sensor Connection Box
Appearance
Speeds up wiring muting sensors.
Cable to connect the E3Z Muting Sensor and
F39-GCN5 Muting Sensor Connection Box.
Used together with the XS3W-M42C-4C2-A to
extend the cable length between the E2Z
Muting Sensor and muting sensor connection
box to more than 0.2 m.
* When the accessory is used, protect it from cutting oil.
Note: 1. Select the same output type for both the safety light curtain/safety multi-light beam (PNP/NPN selection by wiring) and muting sensor
(PNP or NPN model).
2. For details of the XS3W and XS5W, refer to your local OMRON website.
3. Use the F39-JGB-D Extended Plug-Socket Cable to connect the muting sensor connection box with the Intelligent Tap.
The connection example for optical synchronization is shown below.
<Connection example>
Muting sensors
E3Z
(Retro-reflective)
A1
XS3W-M42C-4C2-A
XS5W-D421-@81-F
Available soon
Application
Emitter
Receiver
Root-Plug Cable
for Extended
F39-JGR3K-L
(Gray)
B1
F39-JGR3K-D
(Black)
Extended
Plug-Socket Cable
F39-JG@B-L
(Gray)
F39-JG@B-D
(Black)
Specifications
PNP/NPN selection
Main Unit: M12 socket (5 pin) ×7,
M12 socket (8 pin) ×1
Cable: M12 plug (8 pin) ×1
IP67* rated when mated.
Connectors connected to cable,
M8 socket and M12 plug on cable
ends (4 pin)
Connectors connected to cable,
M12 socket and M12 plug on cable
ends (4 pin)
Muting sensors
E3Z
(Retro-reflective)
B2
A2
CN4
CN3
CN1
CN2
F39-JG@B-D
Intelligent Tap
(Black)
F39-SGIT-IL3
F3SG-SR/PG
Cable
Model
Length
0.5 m
F39-GCN5
0.2 m
XS3W-M42C-4C2-A
1 m
XS5W-D421-C81-F
2 m
XS5W-D421-D81-F
3 m
XS5W-D421-E81-F
5 m
XS5W-D421-G81-F
10 m
XS5W-D421-J81-F
20 m
XS5W-D421-L81-F
AUX
XS5H-D421-@80-F
8
6
4
2
7
5
3
1
XS5H-D521-@G0-A
RESET
14