Omron V460-H Series Connection Manual page 54

Industrial handheld dpm reader
Hide thumbs Also See for V460-H Series:
Table of Contents

Advertisement

● Details of the ETN_ReceiveCheck_instance Function Block (ReceiveCheck)
Instruction
Ethernet
Communications
ReceiveCheck
Receive
Processing
• In-out Variable Table
• Input
Variable
Data type
name
Execute
BOOL
tLength
UINT
• In-out
Variable
Data type
name
Recv_Data
STRING[256]
Recv_Buff
STRING[256]
ErrorID
WORD
ErrorIDEx
DWORD
• Output
Variable
Data type
name
Busy
BOOL
Done
BOOL
Error
BOOL
• Internal Variable Table
Variable name
Data type
Receive_Check
STRING[5]
Calc_Check
STRING[5]
Name
FB/FUN
FB
Name
Description
Executes the function block
Execute
when the value changes from
OFF (FALSE) to ON (TRUE).
Receive
Byte length of receive buffer
Data Length
data
Name
Receive data storage
Receive Data
result
Receive Buffer
Receive data buffer
Error code:
Error
Code reader error =
Information
#16#1000
FCS error = #16#2000
Error: code:
Error
FCS receive
Information
result/Code reader
error code
Name
Description
Busy
Not used
Normal
(Not used in this project.)
End
Error end
Error End
Name
Receive
FCS receive result of
FCS
receive data
Receive
FCS calculation result of
FCS
receive data
Calculation
Value
Graphic
ST expression
expression
ETN_ReceiveCheck_instance
(Execute, Recv_Data,
None
Recv_Buff, Error, ErrorID,
ErrorIDEx);
Valid range
Depends
on data
type.
Depends
on data
type.
Description
Valid range
Depends
on data
type.
Depends
on data
type.
---
---
Valid range
---
---
Description
Valid range
Depends
on data
type.
Depends
on data
type.
9. Project File
Initial
Unit
value
---
---
---
---
Initial
Unit
value
---
---
---
---
---
---
---
---
Initial
Unit
value
---
---
---
---
Initial
Unit
value
---
---
---
---
51