Disinfecting Your Fresh Water System - Winnebago Vita 2020 Manual

Table of Contents

Advertisement

Do not leave the pump on while away from
your motorhome or while driving. In time, a
slow leak in a faucet could drain the water tank,
fill the holding tank, and discharge the house
batteries.
Initial Waterline Priming
1. Ensure that all water drain valves are closed,
including water heater valve.
2. Turn Water Pump switch to "OFF" position.
3. Fill water tank.
4. Open all faucets, hot and cold.
5. Turn ON the Water Pump switch.
6. Close each faucet as it begins to deliver a
steady stream of water (close cold water first).
Leave hot water faucets on until they also
deliver a steady stream of water. This will
ensure that the water heater is filled with
water.
7. Check to ensure the Water Pump stops soon
after all faucets have been closed.
8. The Water Pump is now ready for automatic
operation. The pump will start when a faucet
is opened and stop when the faucet is closed.
Further Information
Refer to the Water Pump manufacturer's
operation, care, and maintenance information
provided in your InfoCase.
Water Pump
•Model 24F: Located inside passenger side rear
compartment. Remove access panel.
-Typical View
Water Pump
•Model 24P: Located at the foot of the bed
cabinet. Remove the door to access.
-Typical View
DISINFECTING YOUR FRESH
WATER SYSTEM
(As required by NFPA
Recreational Vehicles)
To ensure complete disinfection of the potable
water system, it is recommended that the
following procedure be followed on a new
system, one that has not been used for a period of
time, or one that could have become
contaminated.
This procedure is also recommended before
long periods of storage such as over winter.
1. Prepare a chlorine solution using 1 gallon of
water and 1/4 cup of household chlorine
bleach (sodium hypochlorite solution). With
tank empty, pour chlorine solution into the
tank through the gravity fill port.
Use 1 gallon solution for each 15 gallons of
tank capacity. This procedure will result in a
residual chlorine concentration of 50 ppm in
the water system.
NOTE: If a 100 ppm concentration is desired,
use 1/2 cup of household bleach with 1
gallon of water to prepare the chlorine
solution. One gallon of this solution
should be used for each 15 gallons of
tank capacity.
SECTION 7 –
PLUMBING
®
1192 Standard on
7-3

Advertisement

Table of Contents
loading

Table of Contents