Nozzle lance
To replace the seals (1) (2) (3) (4), the purchase of O-Ring kit
code 20019166 is recommended.
ARIA/AIR
4.10.1 Nozzles (mechanical atomization)
Recommended nozzles
 BERGONZO, type B5
 FLUIDICS, type W2
Complete range of nozzles:
Bergonzo B5 45° - 450 - 500 - 550 - 600 - 650 - 700 - 750 - 800
Fluidics W2 50° - 450 - 500 - 550 - 600 - 650 - 700 - 750 - 800
For intermediate delivery levels, choose the nozzle with delivery
slightly higher than that effectively required.
Normally, atomisation angles of 45÷60° are recommended; for
narrow combustion chambers, use nozzles with 30÷35° angles.