Daikin HUBBARD HCU2040PXB1 Installation, Commissioning And Maintenance Manual page 147

Hermetic r744 condensing units
Table of Contents

Advertisement

************
PARALLEL COMPRESSORS
************
Cca01
L1
Cca01
L1
Cca02
L1
Cca02
L1
Cca02
L1
Cca02
L1
Cca03
L1
Cca04
L1
Cca04
L1
Cca04
L1
Cca04
L1
************
CHILLER REGULATION
************
Cab22
Cab22
Cab23
L1
Cab23
Cab23
Cab24
L1
Cab24
Cab25
Cab26
Analog Input
MaskIndex
VarDesc
Bab01
L1
Bab60
L1
Bab02
L1
Bab03
L1
Bab79
Bab59
Bab97
Bab75
L1
Bab11
L1
Bab04
L1
Bab09
L1
Bab61
L1
Bab62
L1
Bab70
L1
Bab71
L1
Bab63
L1
Bab90
L1
Bab13
L1
Bab05
L2
Bbb75
L2
Bab48
L2
Bab49
L1
Bab64
L2
Bab06
L2
Bab07
L2
Bab73
L2
Bab14
L2
Bab65
L2
Bab18
L2
Bab15
L1
Bab16
Bab17
L1
Bab20
L1
Bab22
L1
Bab24
L1
Bab26
L1
Bab28
L1
Bab29
L1
Bab30
L1
Bab31
L1
Bab32
L1
Bab33
L1
Bab34
L1
Bab35
L2
Bab36
L2
Bab37
L2
Bab38
L2
Bab39
L2
Bab40
L2
Bab41
L1
Bab42
L1
Bab43
L1
Bab44
L1
Bab45
L1
Bab46
L1
Bab47
L2
Bab66
L1
Bab67
Bab68
Bab72
L1
Bab98
Bab99
Eeaa04
L1
Eeaa13
L1
Eeaa14
L1
Eeaa15
L1
Eeaa27
L1
Digital input
MaskIndex
Baa56
L1
Baa57
L1
Baada
L1
Baa02
L1
Baa02
L1
Baa03
L1
Baa04
L1
Baa05
L1
Baa06
L1
Baa07
L1
Baa08
L1
Baa09
L1
Baa10
L1
Baa11
L1
Baa12
L1
Baa13
L1
Baa14
L1
Baa15
L1
Baa17
L1
Baa18
L1
Baa19
L1
Baa20
L1
Baa21
L1
Baa22
L1
Baa23
L1
Baa24
L1
Baa25
L1
Baa26
L1
Baa27
L1
Baa28
L1
Baa29
L1
Baa30
L1
Baa32
L1
Baa33
L1
Baa34
L1
Baa35
L1
Baa36
L1
Baa37
L1
Baa38
L1
Baa39
L1
Baa40
L1
Baa41
L1
Baa42
L1
Baa43
L1
Baa44
L1
Baa45
L1
Baa47
L1
Baa48
L1
Baa49
L1
Baa50
L1
Baa51
L1
Baa52
L1
Baa53
L1
Baa54
L1
Baa55
L1
Baa58
L1
Baa59
L1
Baadh
L1
Baadi
Copyright HPL March 2021
Enable parallal compressor
Parallel compressor control mode
Parallel compressor: RPRV activation threshold
Parallel compressor: evalution time on RPRV opening
Parallel compressor: activation threshold
Parallel compressor: deactivation threshold
Offset to RPRV setpoint with parallel compressor active
Parallel compressor regulation (internal management): setpoint
Parallel compressor regulation (internal management): proportional gain
Parallel compressor regulation (internal management): integral time
Parallel compressor regulation (internal management): derivative time
Chiller regulation is enabled on L1
Type of regolation
Setpoint chiller running
Chiller kp value for PID running
Chiller ti value for PID running
Suction setpoint chiller startup
Chiller kp value for PID startup
Chiller ti value for PID Startup
Time of start up duration phase
Suction pressure
Suction setpoint compensation from analog input
Suction pressure backup
Suction temperature
q
Chiller water inlet temperature on L1
Chiller Anti freeze temperature on L1
Discharge pressure
Discharge temperature
Gas cooler pressure
Gas cooler pressure backup
Gas cooler outlet temperature
Gas cooler outlet temperature backup
Gas cooler inlet temperature
Gas cooler setpoint compensation from analog input
Oil reserve pressure
Temperature between the heat exchangers of heat reclaim 1 and 2
Heat Reclaim 1 temperature
Suction pressure
Discharge pressure
Discharge temperature
Heat reclaim 1 request from externa 0/10V signal
Suction setpoint compensation from analog input
Suction pressure backup
Suction temperature
Intercooler temperature
Heat reclaim 2 temperature
Oil reserve pressure
Common oil temperature
External temperature
Room temperature
Common oil temperature
Generic probe 1
Generic probe 2
Generic probe 3
Generic probe 4
Generic probe 5
Discharge temperature of compressor 1
Discharge temperature of compressor 2
Discharge temperature of compressor 3
Discharge temperature of compressor 4
Discharge temperature of compressor 5
Discharge temperature of compressor 6
Discharge temperature of compressor 1
Discharge temperature of compressor 2
Discharge temperature of compressor 3
Discharge temperature of compressor 4
Discharge temperature of compressor 5
Discharge temperature of compressor 6
Oil temperature of compressor 1
Oil temperature of compressor 2
Oil temperature of compressor 3
Oil temperature of compressor 4
Oil temperature of compressor 5
Oil temperature of compressor 6
Oil temperature of compressor 1
Receiver pressure
HPV opening feedback
RPRV opening feedback
HPV setpoint compensation from analog input
Percentage of max power on L1 from analog input
Percentage of max power on L2 from analog input
Heat reclaim 1 water inlet temperature
Heat reclaim 2 water outlet temperature
Heat reclaim 2 water inlet temperature
Heat reclaim 2 request from externa 0/10V signal
Gas cooler bypassed temperature
VarDesc
Common low pressure from pressostat
Common high pressure from pressostat
Compressor inverter warning
Alarm 1 of compressor 1
Alarm of parallel compressor
Alarm 2 of compressor 1
Alarm 3 of compressor 1
Alarm 4 of compressor 1
Alarm 5 of compressor 1
Alarm 6 of compressor 1
Alarm 7 of compressor 1
Alarm 1 of compressor 2
Alarm 2 of compressor 2
Alarm 3 of compressor 2
Alarm 4 of compressor 2
Alarm 5 of compressor 2
Alarm 6 of compressor 2
Alarm 7 of compressor 2
Alarm 1 of compressor 3
Alarm 2 of compressor 3
Alarm 3 of compressor 3
Alarm 4 of compressor 3
Alarm 5 of compressor 3
Alarm 6 of compressor 3
Alarm 7 of compressor 3
Alarm 1 of compressor 4
Alarm 2 of compressor 4
Alarm 3 of compressor 4
Alarm 4 of compressor 4
Alarm 4 of compressor 5
Alarm 6 of compressor 4
Alarm 7 of compressor 4
Alarm 1 of compressor 5
Alarm 2 of compressor 5
Alarm 3 of compressor 5
Alarm 4 of compressor 5
Alarm 5 of compressor 5
Alarm 6 of compressor 5
Alarm 7 of compressor 5
Alarm 1 of compressor 6
Alarm 2 of compressor 6
Alarm 3 of compressor 6
Alarm 4 of compressor 6
Alarm 5 of compressor 6
Alarm 6 of compressor 6
Alarm 7 of compressor 6
Alarm 1 of compressor 7
Alarm 2 of compressor 7
Alarm 1 of compressor 8
Alarm 2 of compressor 8
Alarm 1 of compressor 9
Alarm 2 of compressor 9
Alarm 1 of compressor 10
Alarm 1 of compressor 11
Alarm 1 of compressor 12
Common oil alarm
Liquid level alarm
CO2 leakage alarm
CO2 level alarm
--
--
--
--
--
--
0
NO
990
--
0
%
0
s
0
0
0
0
0
%/10psig
0
s
0
s
--
--
--
--
--
--
0
NO
0
Water outlet temperature
0
0
°F
0
s
1
0
°F
0
s
0
s
VarValue
Uom
Type
Channel
Min
0
0
°F
NTC
---
0
0
0
0
0
0
0
0
0
0
0
0
0
psig
--
---
0
0
0
0
0
0
0
psig
---
---
0
psig
--
---
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
%
---
---
0
VarValue
Type
Channel
0
NO
---
0
NC
--
0
NC
EXP U03
0
NC
---
0
NC
---
0
NC
---
0
NC
---
0
NC
---
0
NC
---
0
NC
---
0
NC
--
0
NC
---
0
NC
---
0
NC
pCO ID05
0
NC
---
0
NC
--
0
NC
--
0
NC
pCO ID05
0
NC
pCO ID06
0
NC
---
0
NC
pCO ID01
0
NC
--
0
NC
---
0
NC
---
0
--
---
0
NC
---
0
NC
---
0
--
---
0
NC
---
0
NC
pCO ID01
0
NC
---
0
NC
pCO ID02
0
NC
---
0
NC
---
0
NC
---
0
NC
---
0
NC
---
0
NC
---
0
NO
--
0
NC
---
0
NC
--
0
NC
---
0
NC
pCO ID01
0
NC
---
0
NC
---
0
NC
--
0
--
---
0
NC
---
0
NC
pCO ID01
0
NC
---
0
NC
---
0
--
pCO ID09
0
NC
---
0
NO
---
0
NC
---
0
NC
---
0
NC
---
0
NC
---
0
--
--
Max
Offset
40
0
0
0
0
0
0
0
256
Page 147 of 169