  • Page 1 Operation manual Daikin Altherma 3 H HT ECH₂O ETSH16P30EF ETSH16P50EF ETSHB16P30EF ETSHB16P50EF ETSX16P30EF ETSX16P50EF Operation manual ETSXB16P30EF English Daikin Altherma 3 H HT ECH₂O ETSXB16P50EF...
  • Page 2: Table Of Contents

    Latest revisions of the supplied documentation may be available on To check the malfunction history..........18 the regional Daikin website or via your installer. Symptom: You are feeling too cold (hot) in your living room..18 Symptom: The water at the tap is too cold ........ 18 The original documentation is written in English.
  • Page 3: User Safety Instructions

    Waste batteries MUST be treated at a specialised treatment facility for reuse. By ensuring waste batteries are disposed of correctly, you will help to prevent potential negative consequences for the environment and human health. ETSH/X(B)16P30+50EF Operation manual Daikin Altherma 3 H HT ECH₂O 4P679469-1 – 2022.02...
  • Page 4: Instructions For Safe Operation

    Dedicated Human Comfort Interface (BRC1HHDA used as of the user interface. room thermostat) Underfloor heating Radiators, heat pump convectors, or fan coil units ▪ If not, you can purge air immediately. Operation manual ETSH/X(B)16P30+50EF Daikin Altherma 3 H HT ECH₂O 4P679469-1 – 2022.02...
  • Page 5: Quick Guide

    NOTICE Water pipe freeze prevention. Even if you turn OFF space heating/cooling operation ([C.2]: Operation > Space heating/cooling), water pipe freeze prevention – if enabled– will remain active. ETSH/X(B)16P30+50EF Operation manual Daikin Altherma 3 H HT ECH₂O 4P679469-1 – 2022.02...
  • Page 6: Domestic Hot Water

    Increase or decrease the slope/offset. When slope is selected: set slope and go to offset. When offset is selected: set offset. Confirm changes and return to the submenu. Operation manual ETSH/X(B)16P30+50EF Daikin Altherma 3 H HT ECH₂O 4P679469-1 – 2022.02...
  • Page 7: Operation

    Slot for WLAN cartridge With the WLAN cartridge, the installer can connect the system to the internet. As user you can then control the system via the Daikin Residential Controller app. Note: This slot cannot be used for SD cards.
  • Page 8: Menu Structure: Overview User Settings

    Only applicable for models where cooling is possible (**) Only accessible by installer (***) Only applicable when WLAN is installed INFORMATION Depending on the selected installer settings and unit type, settings will be visible/invisible. Operation manual ETSH/X(B)16P30+50EF Daikin Altherma 3 H HT ECH₂O 4P679469-1 – 2022.02...
  • Page 9: Possible Screens: Overview

    Go through the list of the main menu. Go to the main menu screen. Holiday mode Enable/disable breadcrumbs. Holiday mode active Item Description a Domestic hot water Domestic hot water Measured tank temperature ETSH/X(B)16P30+50EF Operation manual Daikin Altherma 3 H HT ECH₂O 4P679469-1 – 2022.02...
  • Page 10: Main Menu Screen

    Adjust and automatically apply the desired zones. Shows the applicable symbol temperature. for your additional zone emitter type. Set the leaving water temperature for the additional zone (if present). Operation manual ETSH/X(B)16P30+50EF Daikin Altherma 3 H HT ECH₂O 4P679469-1 – 2022.02...
  • Page 11: Detailed Screen With Values

    Space heating/cooling operation ON Operation Space heating/cooling operation OFF Space heating/cooling Tank 2 Set operation to On or Off. Reading out information To read out information 1 Go to [8]: Information. ETSH/X(B)16P30+50EF Operation manual Daikin Altherma 3 H HT ECH₂O 4P679469-1 – 2022.02...
  • Page 12: Possible Read-Out Information

    [4.2]. To restrict automatic changeover according to a schedule Conditions: You set the space operation mode to Automatic. 1 Go to [4.2]: Space heating/cooling > Operation mode schedule. Operation manual ETSH/X(B)16P30+50EF Daikin Altherma 3 H HT ECH₂O 4P679469-1 – 2022.02...
  • Page 13: Domestic Hot Water Control

    When powerful operation is active, the risk of space heating/cooling and capacity shortage comfort problems is significant. In case of frequent domestic hot water operation, frequent and long space heating/cooling interruptions will happen. ETSH/X(B)16P30+50EF Operation manual Daikin Altherma 3 H HT ECH₂O 4P679469-1 – 2022.02...
  • Page 14: Schedule Screen: Example

    1 Select the day of which you want to clear the content. For example Friday 2 Select Copy. User defined 1 Delete Edit Copy Result: Next to the copied day, "C" is displayed. Operation manual ETSH/X(B)16P30+50EF Daikin Altherma 3 H HT ECH₂O 4P679469-1 – 2022.02...
  • Page 15: Weather-Dependent Curve

    Which type of curve you use to make adjustments, depends on your personal preference. "5.9.4  Using weather-dependent curves" [ 4  17]. Availability The weather-dependent curve is available for: ▪ Main zone - Heating ETSH/X(B)16P30+50EF Operation manual Daikin Altherma 3 H HT ECH₂O 4P679469-1 – 2022.02...
  • Page 16: 2-Points Curve

    For example, if leaving water temperature is in general fine but at low ambient temperatures too cold, raise the slope so that leaving water temperature is heated increasingly more at decreasingly lower ambient temperatures. Operation manual ETSH/X(B)16P30+50EF Daikin Altherma 3 H HT ECH₂O 4P679469-1 – 2022.02...
  • Page 17: Using Weather-Dependent Curves

    When the maximum lower the tank temperature daily by 1°C and check if you still have or minimum setpoint is reached, the curve flattens out. enough hot water. ETSH/X(B)16P30+50EF Operation manual Daikin Altherma 3 H HT ECH₂O 4P679469-1 – 2022.02...
  • Page 18: Maintenance And Service

    To manually recover it via the user interface, go to the Malfunctioning main menu screen and confirm whether the backup heater can take over the heat load or not. Operation manual ETSH/X(B)16P30+50EF Daikin Altherma 3 H HT ECH₂O 4P679469-1 – 2022.02...
  • Page 19: Symptom: The System Is Making Gurgling Noises After Commissioning

    Schedule [3.1] the room when you purge air from the heat emitters or WD curve type [3.C] (read only) collectors. Tank Heat up mode [5.6] Hysteresis [5.9] ETSH/X(B)16P30+50EF Operation manual Daikin Altherma 3 H HT ECH₂O 4P679469-1 – 2022.02...
  • Page 20: Settings Menu

    11 Installer settings: Tables to be filled in by installer 11.2 Settings menu Setting Fill in… Main zone Thermostat type [2.A] Additional zone (if applicable) Thermostat type [3.A] Information Dealer information [8.3] Operation manual ETSH/X(B)16P30+50EF Daikin Altherma 3 H HT ECH₂O 4P679469-1 – 2022.02...
  • Page 24 4P679469-1 0000000$ 4P679469-1 2022.02 Verantwortung für Energie und Umwelt...