FQPSPPW0042M • FQPSPPW0050M
system power and occurred around the same time as
the problem that you are working on and resolve those
first.
FQPSPPW0042M
Explanation: Message: The power sequencer chip
detected a PGOOD_5P0V fault
Severity: Critical
Serviceable: Yes
Call Home Candidate: Yes
Affected Subsystem: Power
Event type: Environmental
Response: Replace the disk drive and fan board.
Replace the system backplane.
FQPSPPW0043M
Explanation: Message: The power sequencer chip
detected a MEM_GOOD0 fault
Severity: Critical
Serviceable: Yes
Call Home Candidate: Yes
Affected Subsystem: Power
Event type: Environmental
Response: Remove the DIMMS attached to CPU 0. If
the problem persists, replace the system backplane.
Otherwise, Reinstall the DIMMS one at a time, IPLing
the system after each DIMM install until the problem
returns. Replace the DIMM that caused the fault to
return.
FQPSPPW0044M
Explanation: Message: The power sequencer chip
detected a MEM_GOOD1 fault
Severity: Critical
Serviceable: Yes
Call Home Candidate: Yes
Affected Subsystem: Power
Event type: Environmental
Response: Remove the DIMMS attached to CPU 1. If
the problem persists, replace the system backplane.
Otherwise, Reinstall the DIMMS one at a time, IPLing
the system after each DIMM install until the problem
returns. Replace the DIMM that caused the fault to
return.
FQPSPPW0045M
Explanation: Message: The power sequencer chip
detected a GPU_PGOOD fault for GPU %x
Severity: Critical
Serviceable: Yes
Call Home Candidate: Yes
Affected Subsystem: Power
Event type: Environmental
Response: Replace the specified GPU. If the problem
persists, then replace the system backplane.
12
Event Codes for the 8335-GTC, 8335-GTG, 8335-GTH, 8335-GTW, and 8335-GTX
FQPSPPW0047M
Explanation: Message: The power sequencer chip
detected a fault on 5.0VCS rail.
Severity: Critical
Serviceable: Yes
Call Home Candidate: Yes
Affected Subsystem: Power
Event type: Environmental
Response: Replace the system backplane.
FQPSPPW0048M
Explanation: Message: The power sequencer chip
detected a fault on 12.0V rail.
Severity: Critical
Serviceable: Yes
Call Home Candidate: Yes
Affected Subsystem: Power
Event type: Environmental
Response: Check for event FQPSPPW0047M and
resolve that first. If the problem persists, replace the
power supplies one at a time until the problem is
resolved. If the problem persists, replace the system
backplane.
FQPSPPW0049M
Explanation: Message: The power sequencer chip
detected a fault on 3.3V rail.
Severity: Critical
Serviceable: Yes
Call Home Candidate: Yes
Affected Subsystem: Power
Event type: Environmental
Response: Check for events FQPSPPW0047M and
FQPSPPW0048M and resolve those first, in that order.
If the problem persists, remove the PCIe adapters. If
the problem persists, replace the system backplane.
Otherwise, reinstall the PCIe adapters one at a time,
IPLing the system after each PCIe install until the
problem returns. Replace the PCIe adapter that caused
the fault to return.
FQPSPPW0050M
Explanation: Message: The power sequencer chip
detected a fault on 1.8V rail.
Severity: Critical
Serviceable: Yes
Call Home Candidate: Yes
Affected Subsystem: Power
Event type: Environmental
Response: Check for events FQPSPPW0047M,
FQPSPPW0048M, and FQPSPPW0049M and resolve
those first, in that order. If the problem persists, replace
the system backplane.