Event type: Unrecoverable Hardware Failure
Response: Replace the specified CPU.
FQPSPPU0091M
Explanation: Message: CPU %x core %y has failed.
Note: %x indicates the CPU number and %y indicates
the CPU core number. To determine the CPU number
and CPU core number, view details for the serviceable
event that sent you here.
Severity: Critical
Serviceable: Yes
Call Home Candidate: Yes
Affected Subsystem: Processing
Event type: Unrecoverable Hardware Failure
Response: Replace the specified CPU.
FQPSPPU0092M
Explanation: Message: An error occurred with a GPU
and automated isolation was not possible
Severity: Critical
Serviceable: Yes
Call Home Candidate: Yes
Affected Subsystem: Processing
Event type: Unrecoverable Hardware Failure
Response: Replace the GPUs one at a time until the
problem is resolved. If the problem persists replace the
system backplane.
FQPSPPW0009M
Explanation: Message: Power Supply %x input out of
range Note: %x indicates the power supply number. To
determine the power supply number, view details for
the serviceable event that sent you here.
Severity: Critical
Serviceable: Yes
Call Home Candidate: No
Affected Subsystem: Power
Event type: Unrecoverable Hardware Failure
Response: Ensure that the AC Power cable is
receiving the correct voltage.
FQPSPPW0012M
Explanation: Message: A system power problem has
occurred
Severity: Critical
Serviceable: Yes
Call Home Candidate: No
Affected Subsystem: Power
Event type: Unrecoverable Hardware Failure
Response: Complete the service action indicated for
any events that are related to power and occurred prior
to this event.
FQPSPPU0091M • FQPSPPW0024M
FQPSPPW0015M
Explanation: Message: Power Supply %y has not been
detected. Note: %x indicates the power supply number.
To determine the power supply number, view details
for the serviceable event that sent you here.
Severity: Critical
Serviceable: Yes
Call Home Candidate: Yes
Affected Subsystem: Power
Event type: Uncorrectable Hardware Failure
Response: Replace the specified power supply.
FQPSPPW0022M
Explanation: Message: Power supply %x is not
functional. Note: %x indicates the power supply
number. To determine the power supply number, view
details for the serviceable event that sent you here.
Severity: Critical
Serviceable: Yes
Call Home Candidate: Yes
Affected Subsystem: Power
Event type: Uncorrectable Hardware Failure
Response: Replace the specified power supply.
FQPSPPW0023M
Explanation: Message: Unable to read the output
current from power supply %x. Note: %x indicates the
power supply number. To determine the power supply
number, view details for the serviceable event that sent
you here.
Severity: Critical
Serviceable: Yes
Call Home Candidate: No
Affected Subsystem: Power
Event type: Communication Failure/Timeout
Response: Ensure the specified power supply is fully
seated and has good input. If the problem persists,
replace the specified power supply.
FQPSPPW0024M
Explanation: Message: Unable to read GPU %x power.
Note: %x indicates the GPU number. To determine the
GPU number, view details for the serviceable event that
sent you here.
Severity: Critical
Serviceable: Yes
Call Home Candidate: No
Affected Subsystem: Power
Event type: Communication Failure/Timeout
Response: If the system was recently installed, moved,
serviced, or upgraded, ensure the specified GPU is
properly seated. Replace the system backplane. Replace
the specified GPU.