Serviceable: Yes
Call Home Candidate: No
Affected Subsystem: Power
Event type: Communication Failure/Timeout
Response: Ensure the power supply and line cord are
properly seated. Replace the power supply. Replace the
system backplane.
FQPSPPW0033M
Explanation: Message: Power supply %x input fault
detected. Note: %x indicates the power supply number.
To determine the power supply number, view details
for the serviceable event that sent you here.
Severity: Critical
Serviceable: Yes
Call Home Candidate: No
Affected Subsystem: Power
Event type: Unrecoverable Hardware Failure
Response: Ensure the input voltage to the specified
power supply is within the operating specifications for
the specified power supply.
FQPSPPW0034M
Explanation: Message: Power supply %x has failed to
power on when it needed to. Note: %x indicates the
power supply number. To determine the power supply
number, view details for the serviceable event that sent
you here.
Severity: Critical
Serviceable: Yes
Call Home Candidate: Yes
Affected Subsystem: Power
Event type: Unrecoverable Hardware Failure
Response: Replace the specfied power supply.
FQPSPPW0035M
Explanation: Message: Power supply %x output
current is too high. Note: %x indicates the power
supply number. To determine the power supply
number, view details for the serviceable event that sent
you here.
Severity: Critical
Serviceable: Yes
Call Home Candidate: Yes
Affected Subsystem: Power
Event type: Unrecoverable Hardware Failure
Response: Replace the specfied power supply.
FQPSPPW0036M
Explanation: Message: Power supply %x output
voltage is too high. Note: %x indicates the power
supply number. To determine the power supply
number, view details for the serviceable event that sent
you here.
Severity: Critical
FQPSPPW0033M • FQPSPPW0041M
Serviceable: Yes
Call Home Candidate: Yes
Affected Subsystem: Power
Event type: Unrecoverable Hardware Failure
Response: Replace the specfied power supply.
FQPSPPW0037M
Explanation: Message: Power supply %x has initiated
a power off due to a failure. Note: %x indicates the
power supply number. To determine the power supply
number, view details for the serviceable event that sent
you here.
Severity: Critical
Serviceable: Yes
Call Home Candidate: Yes
Affected Subsystem: Power
Event type: Unrecoverable Hardware Failure
Response: Replace the specfied power supply.
FQPSPPW0038F
Explanation: Message: The system power failed to
turn on
Severity: Warning
Serviceable: No
Call Home Candidate: No
Affected Subsystem: Power
Event type: Environmental
Response: Look for system events that are related to
system power and occurred around the same time as
the problem that you are working on and resolve those
first.
FQPSPPW0038M
Explanation: Message: GPU %x suffered a power fault
. Note: %x indicates the power supply number. To
determine the power supply number, view details for
the serviceable event that sent you here.
Severity: Critical
Serviceable: Yes
Call Home Candidate: No
Affected Subsystem: Power
Event type: Environmental
Response: Check for serviceable power events and
resolve those.
FQPSPPW0041M
Explanation: Message: The power sequencer chip
detected a fault
Severity: Critical
Serviceable: Yes
Call Home Candidate: Yes
Affected Subsystem: Power
Event type: Environmental
Response: Look for system events that are related to
FQPSPxxxxxxx Event Codes