IBM 8335-GTC Manual page 26

Hide thumbs Also See for 8335-GTC:
Table of Contents

Advertisement

FQPSPPW0025M • FQPSPPW0032M
FQPSPPW0025M
Explanation: Message: Unable to read CPU %x I/O
power. Note: %x indicates the CPU number. To
determine the CPU number, view details for the
serviceable event that sent you here.
Severity: Critical
Serviceable: Yes
Call Home Candidate: No
Affected Subsystem: Power
Event type: Communication Failure/Timeout
Response: If the system was recently installed, moved,
serviced, or upgraded, ensure the specified CPU is
properly seated. Replace the system backplane. Replace
the specified CPU.
FQPSPPW0026M
Explanation: Message: Unable to read CPU %x
memory power. Note: %x indicates the CPU number.
To determine the CPU number, view details for the
serviceable event that sent you here.
Severity: Critical
Serviceable: Yes
Call Home Candidate: No
Affected Subsystem: Power
Event type: Communication Failure/Timeout
Response: If the system was recently installed, moved,
serviced, or upgraded, ensure the specified CPU is
properly seated. Replace the system backplane. Replace
the specified CPU.
FQPSPPW0027M
Explanation: Message: Unable to read CPU %x power.
Note: %x indicates the CPU number. To determine the
CPU number, view details for the serviceable event that
sent you here.
Severity: Critical
Serviceable: Yes
Call Home Candidate: No
Affected Subsystem: Power
Event type: Communication Failure/Timeout
Response: If the system was recently installed, moved,
serviced, or upgraded, ensure the specified CPU is
properly seated. Replace the system backplane. Replace
the specified CPU.
FQPSPPW0028M
Explanation: Message: Unable to read power supply
%x input power. Note: %x indicates the power supply
number. To determine the power supply number, view
details for the serviceable event that sent you here.
Severity: Critical
Serviceable: Yes
Call Home Candidate: No
Affected Subsystem: Power
Event type: Communication Failure/Timeout
10
Event Codes for the 8335-GTC, 8335-GTG, 8335-GTH, 8335-GTW, and 8335-GTX
Response: Ensure the power supply and line cord are
properly seated. Replace the power supply. Replace the
system backplane.
FQPSPPW0029M
Explanation: Message: Unable to read storage %x
power. Note: %x indicates the storage device number.
To determine the storage device number, view details
for the serviceable event that sent you here.
Severity: Critical
Serviceable: Yes
Call Home Candidate: No
Affected Subsystem: Power
Event type: Communication Failure/Timeout
Response: If the system was recently installed, moved,
serviced, or upgraded, ensure the specified storage
device is properly seated, and ensure all cables between
the system backplane and disk drive and fan card are
properly seated. Replace the system backplane. Replace
the disk drive and fan card.
FQPSPPW0030M
Explanation: Message: Unable to read total power
consumption
Severity: Critical
Serviceable: Yes
Call Home Candidate: No
Affected Subsystem: Power
Event type: Communication Failure/Timeout
Response: Flash and or update the BMC firmware. If
the problem persists, replace the system backplane. For
information about updating system firmware, see
Getting fixes.
FQPSPPW0031M
Explanation: Message: Unable to read power supply
%x input voltage. Note: %x indicates the power supply
number. To determine the power supply number, view
details for the serviceable event that sent you here.
Severity: Critical
Serviceable: Yes
Call Home Candidate: No
Affected Subsystem: Power
Event type: Communication Failure/Timeout
Response: Ensure the power supply and line cord are
properly seated. Replace the power supply. Replace the
system backplane.
FQPSPPW0032M
Explanation: Message: Unable to read power supply
%x output voltage. Note: %x indicates the power
supply number. To determine the power supply
number, view details for the serviceable event that sent
you here.
Severity: Critical

Advertisement

Table of Contents
loading

This manual is also suitable for:

8335-gtg8335-gth8335-gtw8335-gtx

Table of Contents