IBM Power System AC922 Installing
IBM Power System AC922 Installing

IBM Power System AC922 Installing

Hide thumbs Also See for Power System AC922:

Advertisement

Quick Links

Power Systems
Installing the System and Ordered Parts
for the IBM Power System AC922 (8335-
GTX)
IBM

Advertisement

Table of Contents
loading

Summary of Contents for IBM Power System AC922

  • Page 1 Power Systems Installing the System and Ordered Parts for the IBM Power System AC922 (8335- GTX)
  • Page 2 Note Before using this information and the product it supports, read the information in “Safety notices” on page v, “Notices” on page 113, the IBM Systems Safety Notices manual, G229-9054, and the IBM Environmental Notices and User Guide, Z125–5823. ®...
  • Page 3: Table Of Contents

    Sensor status............................97 Removing and replacing covers......................98 Service and operating positions......................101 Removing and replacing power cords....................106 Notices......................113 Accessibility features for IBM Power Systems servers................114 Privacy policy considerations ......................... 115 Trademarks..............................115 Electronic emission notices........................116 Class A Notices...........................116 Class B Notices...........................119...
  • Page 5: Safety Notices

    Das Produkt ist nicht für den Einsatz an Bildschirmarbeitsplätzen im Sinne § 2 der Bildschirmarbeitsverordnung geeignet. Laser safety information IBM servers can use I/O cards or features that are fiber-optic based and that utilize lasers or LEDs. Laser compliance IBM servers may be installed inside or outside of an IT equipment rack.
  • Page 6 • To avoid hazardous conditions due to uneven mechanical loading, always install the heaviest devices in the bottom of the rack cabinet. Always install servers and optional devices starting from the bottom of the rack cabinet. vi Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 7 • Rack-mounted devices are not to be used as shelves or work spaces. Do not place objects on top of rack-mounted devices. In addition, do not lean on rack mounted devices and do not use them to stabilize your body position (for example, when working from a ladder). •...
  • Page 8 DANGER: Hazardous voltage, current, or energy levels are present inside any component that has this label attached. Do not open any cover or barrier that contains this label. (L001) (L002) viii Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 9 DANGER: Rack-mounted devices are not to be used as shelves or work spaces. Do not place objects on top of rack-mounted devices. In addition, do not lean on rack-mounted devices and do not use them to stabilize your body position (for example, when working from a ladder). Stability hazard: •...
  • Page 10 DC power cables. To remove all hazardous voltages, disconnect all power cords and power cables. (L003) (L007) CAUTION: A hot surface nearby. (L007) x Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 11 Exchange only with the IBM-approved part. Recycle or discard the battery as instructed by local regulations. In the United States, IBM has a process for the collection of this battery. For information, call 1-800-426-4333. Have the IBM part number for the battery unit available when you call.
  • Page 12 Be sure winch is locked in position before releasing handle. Read instruction page before operating this winch. Never allow winch to unwind freely. xii Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 13 Freewheeling will cause uneven cable wrapping around winch drum, damage cable, and may cause serious injury. • This TOOL must be maintained correctly for IBM Service personnel to use it. IBM shall inspect condition and verify maintenance history before operation. Personnel reserve the right not to use TOOL if inadequate.
  • Page 14 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 15: Installing And Configuring The System

    Before you begin Read the following documents before you install the server: • The latest version of this document is maintained online, see Installing the IBM Power System AC922 (8335-GTC, 8335-GTG, and 8335-GTH) or IBM Power System AC922 (8335-GTW and 8335-GTX) (http://www.ibm.com/support/knowledgecenter/POWER9/p8eik/p8eik_install_kickoff.htm).
  • Page 16: Determining And Marking The Location In The Rack

    3. If necessary, remove the filler panels to allow access to the inside of the rack enclosure where you plan to place the system unit, as shown in Figure 1 on page 3. 2 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 17: Installing The 8335-Gtw Or 8335-Gtx System By Using Fixed Rails

    Figure 1. Removing the filler panels 4. Facing the front of the rack and working from the right side, use tape, a marker, or pencil to mark the lower hole of each EIA unit. Mark the rack such that the mark can also be seen from the rear of the rack. 5.
  • Page 18 5. Install the screws on either side of the system to secure the system to the rack. 6. Attach the front cover to the front of the system. See Figure 2 on page 5. 4 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 19 Figure 2. Installing the server in the rack 7. Connect the water hoses at the rear of the rack to the manifold, as shown in the following figure. Ensure that you plug the male hose into the female manifold plug, and plug the female hose into the male manifold plug.
  • Page 20: Setting Up A Preinstalled Server

    Prerequisite for installing the rack-mounted server Learn about the prerequisites for installing the server. Before you begin Read the following documents before you install the server: 6 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 21 • The latest version of this document is maintained online, see Installing the IBM Power System AC922 (8335-GTC, 8335-GTG, and 8335-GTH) or IBM Power System AC922 (8335-GTW and 8335-GTX) (http://www.ibm.com/support/knowledgecenter/POWER9/p8eik/p8eik_install_kickoff.htm). • To plan your server installation, see Planning for the system (http://www.ibm.com/support/ knowledgecenter/POWER9/p9ia4/p9ia4_90x_kickoff.htm).
  • Page 22 For details, see ../p9ei3/ p9ei3_thermal_mode.dita. ® ™ Power Systems servers use a baseboard management controller (BMC) for system service management, monitoring, maintenance, and control. 8 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 23: Completing Server Setup

    3. You can receive important technical information and updates for specific IBM Support tools and resources by subscribing to receive updates. To subscribe to receive updates, complete the following steps: a.
  • Page 24: Installing A Disk Drive

    1. Determine the slot in which you want to install a disk drive. The disk drive slots are in the front of the system in positions 5 and 6, as shown in Figure 5 on page 11. 10 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 25 Figure 5. Drive locations; positions 5 and 6 2. Remove the front cover. For instructions, see “Removing the front cover from an 8335-GTC, 8335- GTG, 8335-GTH, 8335-GTW, or 8335-GTX system” on page 100. 3. Attach the electrostatic discharge (ESD) wrist strap. The ESD wrist strap must be connected to an unpainted metal surface until the service procedure is completed, and if applicable, until the service access cover is replaced.
  • Page 26 Important: Ensure that the disk drive is fully seated and is all the way into the system. 6. Lock the disk drive bay handle (A) by pushing in the handle release. See Figure 7 on page 13. 12 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 27 Figure 7. Disk drive lock detail 7. Configure the installed disk drive for your environment. After you insert the new disk drive, you must scan for the device. Choose one of the following options depending on the operating system that you are using: •...
  • Page 28: Upgrading Memory

    The ESD wrist strap must be connected to an unpainted metal surface until the service procedure is completed, and if applicable, until the service access cover is replaced. 14 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 29 Attention: • Attach an electrostatic discharge (ESD) wrist strap to the front ESD jack, to the rear ESD jack, or to an unpainted metal surface of your hardware to prevent the electrostatic discharge from damaging your hardware. • When you use an ESD wrist strap, follow all electrical safety procedures. An ESD wrist strap is used for static control.
  • Page 30 Unlock each memory module by pushing the locking tabs away from the memory module, in the direction shown in Figure 10 on page 17. The lever action of opening the tabs pushes the memory module out of the slot. 16 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 31 Figure 10. Removing memory modules b) Hold the memory module by the edges and pull it out of the slot. 5. Place the memory module on an ESD mat. 6. Repeat steps “4” on page 16 - “5” on page 17 until all the memory modules are removed. Install the memory modules: 7.
  • Page 32 8. Repeat step “7” on page 17 until all of the memory modules are installed. 9. Replace the air baffles (A) and (B) as shown in Figure 12 on page 19. Carefully move the baffles around the hoses. 18 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 33: Installing Pcie Adapters

    Figure 12. Replacing the memory air baffles What to do next Prepare the system for operation. For instructions, see “Preparing the 8335-GTC, 8335-GTG, 8335-GTH, 8335-GTW, or 8335-GTX system for operation after you remove and replace internal parts” on page 94. Installing PCIe adapters in the 8335-GTG, 8335-GTH, or 8335-GTX system Find information about removing, installing, using, and managing Peripheral Component Interconnect Express (PCIe) adapters for the system.
  • Page 34: Pcie Adapter Placement Rules And Slot Priorities For The 8335-Gtg, 8335-Gth, Or 8335-Gtx System

    CPU 0 length PCIe4 x8 Half-height, half- CPU 1 (shared) length PCIe4 x16 Half-height, half- CPU 1 length PCIe4 x16 Half-height, half- CPU 0 length 20 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 35 PCIe adapter placement rules Use this information to select slots for installing PCIe adapters in the system. Table 4 on page 21 provides information about the adapters, the slot priorities in the system they are supported on, and the maximum number of adapters that can be installed in the supported system. The link that appears in the feature code column provides more technical information specific to the PCIe adapter.
  • Page 36: Pcie Adapters By Feature Code

    EC67; CCIN 2CF3); Adapter part number: 01FT742 EC6E PCIe4 x16, 1-port HDR 100 Gb InfiniBand ConnectX-6 adapter (FC EC6E; CCIN 590D); Adapter part number: 02CM915 22 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 37 Table 5. PCIe adapters supported in the 8335-GTG, 8335-GTH, or 8335-GTX system (continued) Feature code Description EC6G PCIe4 x16, 2-port HDR 100 Gb InfiniBand ConnectX-6 adapter (FC EC6G; CCIN 590E); Adapter part number: 02CM912 EL3Z PCIe2 LP 2-port 10 GbE BaseT RJ45 adapter (FC EL3Z and FC EN0X; CCIN 2CC4);...
  • Page 38 Figure 14. PCIe3 LP 2-port 10 Gb NIC & RoCE SR/Cu Adapter (FC EC2R) 24 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 39 I/O bus architecture PCIe3 x8 Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. Voltage 3.3 V, 12 V Installing and configuring the 8335-GTX 25...
  • Page 40 OM3 or OM4 cable, the characteristics of the OM2 cable apply to the entire length of the cables. The following table shows the supported distances for the different fiber optic cable types at different link speeds. 26 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 41 • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html). • For support details, see the Linux Alert website (http://www14.software.ibm.com/webapp/set2/sas/f/ lopdiags/info/LinuxAlerts.html).
  • Page 42 Figure 16. PCIe3 LP 2-port 25/10 Gb NIC & RoCE SFP28 Adapter (FC EC2T) 28 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 43 I/O bus architecture PCIe3 x8 Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. Voltage 3.3 V, 12 V. Installing and configuring the 8335-GTX 29...
  • Page 44 OM2 cables must not be connected to OM3 or OM4 cables. However, if an OM2 cable is connected to an OM3 or OM4 cable, the characteristics of the OM2 cable apply to the entire length of the 30 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 45 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 46 The adapter allows full bandwidth for a single port in a PCIe3 slot and up to 128 Gb/s minus overheads for both ports. Figure 18. PCIe3 2-port 100 GbE NIC & RoCE QSFP28 Adapter 32 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 47 See FC EB2B, EB2H, and ECBN for a 1 M, 3 M, and 5 M copper cables. Transceivers IBM qualifies and supports QSFP28 optical transceiver (FC EB59) to install into the adapter. Customers can also use their own optical cabling and QSP28 optical transceiver for the other end.
  • Page 48 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 49 FC EC5A, EC5B, EC5G, EC6U, and EC6V are all the same adapters with different feature codes. FC EC5A, EC5G, and EC6U are low-profile adapters. FC EC5B and EC6V are full-height adapters. FC EC5A, EC5B, and EC5G are supported on AIX or Linux operating systems. FC EC6U and EC6V are supported on IBM i operating system.
  • Page 50 For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. Voltage 3.3 V, 12 V. 36 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 51 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 52 For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. 38 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 53 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 54 PCIe Gen3 I/O drawer. Figure 21. PCIe3 x8 NVMe 6.4 TB SSD NVMe Flash Adapter Specifications Item Description Adapter FRU number 01LK435 I/O bus architecture PCIe3 x8 40 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 55 • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the NVMe management tool can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/set2/sas/f/lopdiags/home.html). • For support details, see the Linux Alert website (http://www14.software.ibm.com/webapp/set2/sas/f/ lopdiags/info/LinuxAlerts.html).
  • Page 56 For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. 42 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 57 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 58 For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. 44 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 59 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 60 Figure 24. 2-port 100 GbE RoCE En Connectx-5 Gen4 PCIe x16 adapter (FC EC66) 46 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 61 (CHANGE TO LINK) Cable and transceiver matrix. Note: For 40G, IBM offers DAC cables up to 3 M. QSFP+ base transceivers are included on each end of these cables. See FC EB2B and EB2H for a 1 M and 3 M copper cables.
  • Page 62 QSFP+ 40G BASE-SR4 optical transceiver MTP/MPO cable (purchased separately) • FC EB2J - 10 M • FC EB2K - 30 M Voltage 3.3 V, 12 V 48 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 63 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 64 InfiniBand adapter. Figure 26. 1-port HDR 100 Gb InfiniBand ConnectX-6 adapter (FC EC6E) Specifications Item Description Adapter FRU number 02CM915 I/O bus architecture PCIe4 x16 50 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 65 GTH, or 8335-GTX system. Cables For HDR 100 Gb, IBM offers either Direct Attach Copper (DAC) cables up to 2 M or Active Optical Cables (AOC) up to 100 M. QSFP56 based transceivers are included on each end of these cables.
  • Page 66 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 67 supports enhanced data rate (EDR) copper and optical cables when connecting to EDR 100 Gb or HDR 200 Gb InfiniBand switches. See “Cable matrix” on page 54 for more details. ® Note: The Virtual Protocol Interconnect (VPI) feature is not supported on this adapter. The adapter must be used only as an InfiniBand adapter.
  • Page 68 GTH, or 8335-GTX system. Cables For HDR 100 Gb, IBM offers either Direct Attach Copper (DAC) cables up to 2 M or Active Optical Cables (AOC) up to 100 M. QSFP56 based transceivers are included on each end of these cables.
  • Page 69 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 70 (UDP), TCP segmentation Offload (TSO) for IPv4 and IPv6. • Supports TCP segmentation or large send offload • Supports EEPROM-SPI and single EEPROM 56 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 71 Figure 28. PCIe2 2-port 10 GbE BaseT RJ45 adapter (FC EL55 or FC EN0W) Figure 29. PCIe2 LP 2-port 10 GbE BaseT RJ45 adapter (FC EL3Z or FC EN0X) Installing and configuring the 8335-GTX 57...
  • Page 72 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 73 The adapter provides two ports of 16 Gb Fibre Channel capability using SR optics. Each port can provide up to 16 Gb Fibre Channel functions simultaneously. Each port provides single initiator capability over a fibre link or with NPIV, multiple initiator capability is provided.
  • Page 74 For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on. Voltage 3.3 V, 12 V 60 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 75 Form factor Short, low-profile FC compatibility 4, 8, 16 Gb Cables Cables are the responsibility of the customer. Use multimode fiber optic cables with shortwave lasers that adhere to the following specifications: • OM4: Multimode 50/125 micron fiber, 4700 MHz x km bandwidth •...
  • Page 76 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 77 PCIe2 4-port 1 GbE adapter (FC 5260, FC 5899, FC EL4L, and FC EL4M; CCIN 576F) Learn about the specifications and operating system requirements for the feature code (FC) 5260, FC 5899, FC EL4L, and EL4M adapters. Overview FC 5260, FC EL4M, FC 5899, and FC EL4L are the same adapter with different feature codes. FC 5260 and EL4M are low-profile adapters and the FC 5899 and EL4L are full-height adapters.
  • Page 78 Figure 31. FC 5260 and FC EL4M PCIe2 4-port 1 GbE adapter 64 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 79 Adapter FRU number 74Y4064 Wrap plug 10N7405 Note: Wrap plugs are not included with the card and cannot be purchased from IBM. I/O bus architecture PCIe2 x4 Slot requirement For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/...
  • Page 80 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 81 PCIe3 x8 2-port Fibre Channel (32 Gb/s); (FC EN1A, EN1B, EL5U, and EL5V; CCIN 578F) Learn about the specifications and operating system requirements for feature code (FC) EN1A, EN1B, EL5U, and EL5V adapters. Overview FC EN1A, EN1B, EL5V, and EL5U are electronically identical. FCs EN1A and EL5U are full-height adapters, and FCs EN1B and EL5V are low-profile adapters.
  • Page 82 For details about slot priorities, maximums, and placement rules, see PCIe adapter placement rules and slot priorities (http://www.ibm.com/support/knowledgecenter/POWER9/p9eab/ p9eab_mtm_pciplacement.htm) and select the system you are working on.. Voltage 3.3 V, 12 V. Form factor Short, low-profile. 68 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 83 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 84 (UDP), TCP segmentation Offload (TSO) for IPv4 and IPv6. • Supports TCP segmentation or large send offload • Supports EEPROM-SPI and single EEPROM 70 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 85 Figure 34. PCIe2 4-Port (10 Gb + 1 GbE) SR / Copper SFP +RJ45 adapter (FC EN0S and FC EN0U) Note: The ports are numbered from top to bottom as T1, T2, and so on for the AIX and IBM i operating systems.
  • Page 86 Figure 35. PCIe2 LP 4-port (10Gb+1GbE) SR / Copper SFP +RJ45 adapter (FC EN0T and FC EN0V) Note: The ports are numbered from top to bottom of the adapter as T1, T2, and so on for the AIX and IBM i operating systems.
  • Page 87 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 88 (UDP), TCP segmentation Offload (TSO) for IPv4 and IPv6. • Supports TCP segmentation or large send offload • Supports EEPROM-SPI and single EEPROM 74 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 89 12R9314 (SFP+ SR wrap plug) 10N7405 (1 Gb UTP wrap plug) Note: These wrap plugs are not included with the card. 12R9314 (FC ECW0) is the only wrap plug that can be purchased from IBM. Installing and configuring the 8335-GTX 75...
  • Page 90 • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 91 PCIe2 LP 4-port (10 Gb + 1 GbE) Copper SFP+RJ45 Adapter (FC EN0V; CCIN 2CC3) Learn about the specifications and operating system requirements for the feature code (FC) EN0V adapter. Overview The PCIe2 LP 4-port (10 Gb + 1 GbE) Copper SFP+RJ45 Adapter is a PCI Express (PCIe) generation 2, x8, short form-factor, low-profile adapter.
  • Page 92 10N7405 (1 Gb UTP wrap plug) Note: Wrap plugs are not included with the card and cannot be purchased from IBM. I/O bus architecture PCIe2 x8 78 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 93: Installing A Pcie Adapter In The 8335-Gtg, 8335-Gth, Or 8335-Gtx System

    • Power Systems Prerequisites (http://www14.software.ibm.com/support/customercare/iprt/home). • IBM SSIC (System Storage Interoperation Center) (http://www-03.ibm.com/systems/support/storage/ ssic/interoperability.wss). • The latest version of the device driver or IBM Power RAID adapter utilities (iprutils) can be downloaded from the IBM Service and Productivity Tools website (http://www14.software.ibm.com/webapp/ set2/sas/f/lopdiags/home.html).
  • Page 94 Figure 38. Rear view of a system with PCIe slots indicated 3. Remove the PCIe slot cover as shown in Figure 39 on page 81. 80 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 95 Figure 39. Removing the PCIe slot cover 4. If needed, label and remove any plugs that extend out of the PCIe adapter. 5. Insert the adapter, aligning it properly and inserting it fully into the slot as shown in Figure 40 on page Installing and configuring the 8335-GTX 81...
  • Page 96: Common Procedures For Servicing Or Installing Features

    The installation, removal, and replacement procedures provide the step- by-step processes that are required to service your system. DANGER: When working on or around the system, observe the following precautions: 82 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 97 Electrical voltage and current from power, telephone, and communication cables are hazardous. To avoid a shock hazard: • If IBM supplied the power cord(s), connect power to this unit only with the IBM provided power cord. Do not use the IBM provided power cord for any other product.
  • Page 98 • Consideration should be given to the connection of the equipment to the supply circuit so that overloading of the circuits does not compromise the supply wiring or overcurrent protection. To 84 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 99 provide the correct power connection to a rack, refer to the rating labels located on the equipment in the rack to determine the total power requirement of the supply circuit. • (For sliding drawers.) Do not pull out or install any drawer or feature if the rack stabilizer brackets are not attached to the rack or if the rack is not bolted to the floor.
  • Page 100 CAUTION: Hazardous energy present. Voltages with hazardous energy might cause heating when shorted with metal, which might result in splattered metal, burns, or both. (L005) 86 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 101: Identifying The System That Contains The Part To Replace

    LEDs on the 8335-GTC, 8335-GTG, 8335-GTH, 8335-GTW, or 8335-GTX system Use this information as a guide to the LEDs on the IBM Power System AC922 (8335-GTC, 8335-GTG, and 8335-GTH) or IBM Power System AC922 (8335-GTW and 8335-GTX) system.
  • Page 102 Figure 41. Front LEDs with bezel on Figure 42. Front LEDs with bezel off 88 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 103 Figure 43. Rear LEDs LED indicators are on the following parts: • At the front of the system: – Disk drives (green LED indicates activity; amber LED indicates a problem). – Fans (green LED indicates activity; amber LED indicates a problem). •...
  • Page 104: Preparing The System To Remove And Replace Internal Parts

    Note: The system might be equipped with redundant power supply. Before you continue with this procedure, ensure that all power to your system is disconnected. (L003) 90 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 105 Installing and configuring the 8335-GTX 91...
  • Page 106 ESD mat. d) Repeat steps “9.a” on page 92 - “9.c” on page 92 for the other power supply. 92 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 107 Figure 44. Removing the power supplies from the system 10. Place the system into the service position. For instructions, see “Placing an 8335-GTC, 8335-GTG, 8335-GTH, 8335-GTW, or 8335-GTX system into the service position” on page 101. CAUTION: Do not place any object on top of a rack-mounted device unless that rack-mounted device is intended for use as a shelf.
  • Page 108: Preparing The System For Operation

    Slide the power supply into the system until the latch (B) locks in place. d) Repeat steps “4.a” on page 94 - “4.c” on page 94 for the other power supply. 94 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 109 8. If the BMC card was replaced continue to the next step, otherwise go to step “11” on page 95. 9. Configure the BMC IP address. For instructions, see Configuring the BMC IP address (www.ibm.com/support/knowledgecenter/ POWER9/p9eih/p9eih_configuring_bmc_ip.htm). 10. Enter the network settings that you recorded earlier.
  • Page 110: Starting And Stopping The System

    Starting and stopping the 8335-GTC, 8335-GTG, 8335-GTH, 8335-GTW, or 8335-GTX system Learn how to start and stop the IBM Power System AC922 (8335-GTC, 8335-GTG, and 8335-GTH) or IBM Power System AC922 (8335-GTW and 8335-GTX) system to perform a service action or system upgrade operation.
  • Page 111: Sensor Status

    Stopping the 8335-GTC, 8335-GTG, 8335-GTH, 8335-GTW, or 8335-GTX system You can use the power button or a command to stop the system. Procedure • You can press and hold the power button to stop and power off the system. Figure 47. Power button •...
  • Page 112: Removing And Replacing Covers

    Removing and replacing covers on an 8335-GTC, 8335-GTG, 8335-GTH, 8335-GTW, or 8335-GTX system Learn how to remove and replace the covers for an IBM Power System AC922 (8335-GTC, 8335-GTG, and 8335-GTH) or IBM Power System AC922 (8335-GTW and 8335-GTX) system so that you can access the hardware parts or service the system.
  • Page 113 Figure 48. Removing the cover 3. While you press down on latch (B) and touch point (C), slide the cover (D) towards the rear of the system unit. When the front of the service access cover clears the upper frame ledge, lift the cover up and off the system unit.
  • Page 114 3. If applicable, remove the screws that are on both sides of the cover to disengage the cover from the system unit. 4. Pull the cover away from the system. 100 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 115: Service And Operating Positions

    Service and operating positions for the 8335-GTC, 8335-GTG, 8335-GTH, 8335-GTW, or 8335-GTX system Learn how to place on an IBM Power System AC922 (8335-GTC, 8335-GTG, and 8335-GTH) or IBM Power System AC922 (8335-GTW and 8335-GTX) system into the service or operating position.
  • Page 116 2. For a water-cooled system, label and disconnect the water hoses at the manifold. Pull the coupling toward you to disconnect the water hoses as shown in Figure 51 on page 103. 102 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 117 Figure 51. Disconnecting the water hoses 3. Remove the screws on either side of the system that secure the system to the rack. 4. While one person is supporting the weight of the front of the system, have the second person move to the rear of the system and push the system partially out of the rack.
  • Page 118 Figure 52. Placing the system into the operating position 3. Replace the screws on either side of the system that secure the system to the rack. 104 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 119 Fixed rails Use this procedure when your system is installed using fixed rails. Before you begin CAUTION: This system requires two people to replace the system into the rack. Do not begin this procedure unless physical assistance is available to replace the system into the rack. Note: When you place the system into the operating position, you must ensure that all stability plates are firmly installed to prevent the rack from toppling.
  • Page 120: Removing And Replacing Power Cords

    Figure 54 on page 107 and Figure 55 on page 108 shows how to loop the cables. 106 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 121 Figure 54. Routing the power cord loop in the cable management arm Installing and configuring the 8335-GTX 107...
  • Page 122 Note: This system might be equipped with two or more power supplies. If the removing and replacing procedures require the power to be off, then ensure that all the power sources to the system are disconnected. 108 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 123 Figure 56. Removing the power cords from the system Connecting power cords to an 8335-GTC, 8335-GTG, 8335-GTH, 8335-GTW, or 8335-GTX system To connect a power cord, complete the steps in this procedure. Procedure 1. Open the rear rack door on the system unit that you are servicing. 2.
  • Page 124 Figure 58. Routing the power cord loop in the cable management arm 110 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 125 Figure 59. Power cord loop with sidewall routing 4. Close the rack door at the rear of the system. Installing and configuring the 8335-GTX 111...
  • Page 126 112 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 127: Notices

    Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead.
  • Page 128: Accessibility Features For Ibm Power Systems Servers

    This product uses standard navigation keys. Interface information The IBM Power Systems servers user interfaces do not have content that flashes 2 - 55 times per second. The IBM Power Systems servers web user interface relies on cascading style sheets to render content properly and to provide a usable experience.
  • Page 129: Privacy Policy Considerations

    Contact the vendor for accessibility information about its products. Related accessibility information In addition to standard IBM help desk and support websites, IBM has a TTY telephone service for use by deaf or hard of hearing customers to access sales and support services:...
  • Page 130: Electronic Emission Notices

    Electronic emission notices Class A Notices The following Class A statements apply to the IBM servers that contain the POWER9 processor and its features unless designated as electromagnetic compatibility (EMC) Class B in the feature information. When attaching a monitor to the equipment, you must use the designated monitor cable and any interference suppression devices supplied with the monitor.
  • Page 131 Tel: 914-499-1900 Der verantwortliche Ansprechpartner des Herstellers in der EU ist: IBM Deutschland GmbH Technical Relations Europe, Abteilung M456 IBM-Allee 1, 71139 Ehningen, Germany Tel: +49 (0) 800 225 5426 email: HalloIBM@de.ibm.com Generelle Informationen: Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 / EN 55032 Klasse A.
  • Page 132 Proper cables and connectors are available from IBM-authorized dealers. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors 118 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 133: Class B Notices

    Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung von IBM verändert bzw.
  • Page 134 This statement applies to products greater than 20 A, single phase. This statement applies to products greater than 20 A per phase, three-phase. Japan Voluntary Control Council for Interference (VCCI) Notice 120 Power Systems: Installing the System and Ordered Parts for the IBM Power System AC922 (8335-GTX)
  • Page 135: Terms And Conditions

    Permissions for the use of these publications are granted subject to the following terms and conditions. Applicability: These terms and conditions are in addition to any terms of use for the IBM website. Personal Use: You may reproduce these publications for your personal, noncommercial use provided that all proprietary notices are preserved.
  • Page 136 IBM reserves the right to withdraw the permissions granted herein whenever, in its discretion, the use of the publications is detrimental to its interest or, as determined by IBM, the above instructions are not being properly followed.
  • Page 138 IBM®...

This manual is also suitable for:

8335-gtx

Table of Contents