FQPSPCA0059M • FQPSPCA0066M
Affected Subsystem: Cooling
Event type: Communication Failure/Timeout
Response: Ensure the specified fan is fully seated. If
the problem persists, replace the specified fan. If the
problem continues to persist, replace the fan card.
FQPSPCA0059M
Explanation: Message: Unable to read ambient
temperature
Severity: Critical
Serviceable: Yes
Call Home Candidate: No
Affected Subsystem: Cooling
Event type: Communication Failure/Timeout
Response: If the system was recently installed, moved,
serviced, or upgraded, ensure the operator panel cable
is fully seated.
FQPSPCA0060M
Explanation: Message: Unable to read DIMM %x
power consumption. Note: %x indicates the DIMM
number. To determine the DIMM number, view details
for the serviceable event that sent you here.
Severity: Critical
Serviceable: Yes
Call Home Candidate: No
Affected Subsystem: Cooling
Event type: Communication Failure/Timeout
Response: If the system was recently installed, moved,
serviced, or upgraded, ensure the specified DIMM is
fully seated. Replace the DIMM. Replace the system
backplane. Replace the CPU.
FQPSPCA0061M
Explanation: Message: Unable to read GPU %x core
temperature. Note: %x indicates the GPU number. To
determine the GPU number, view details for the
serviceable event that sent you here.
Severity: Critical
Serviceable: Yes
Call Home Candidate: No
Affected Subsystem: Cooling
Event type: Communication Failure/Timeout
Response: If the system was recently installed, moved,
serviced, or upgraded, ensure the specified GPU is
fully seated. Replace the system backplane. Replace the
GPU.
FQPSPCA0062M
Explanation: Message: Unable to read CPU %x core
%y temperature. Note: %x indicates the CPU number
and %y indicates the core number. To determine the
CPU number, view details for the serviceable event that
sent you here.
Severity: Critical
2
Event Codes for the 8335-GTC, 8335-GTG, 8335-GTH, 8335-GTW, and 8335-GTX
Serviceable: Yes
Call Home Candidate: No
Affected Subsystem: Cooling
Event type: Communication Failure/Timeout
Response: If the system was recently installed, moved,
serviced, or upgraded, ensure the specified CPU is fully
seated. Replace the system backplane. Replace the CPU.
FQPSPCA0063M
Explanation: Message: Unable to read CPU %x VCS
voltage regulator temperature. Note: %x indicates the
CPU number. To determine the CPU number, view
details for the serviceable event that sent you here.
Severity: Critical
Serviceable: Yes
Call Home Candidate: No
Affected Subsystem: Cooling
Event type: Communication Failure/Timeout
Response: Replace the system backplane.
FQPSPCA0064M
Explanation: Message: Power supply %x fan has
failed. Note: %x indicates the power supply number. To
determine the power supply number, view details for
the serviceable event that sent you here.
Severity: Critical
Serviceable: Yes
Call Home Candidate: Yes
Affected Subsystem: Cooling
Event type: Unrecoverable Hardware Failure
Response: Ensure the power supply fan is not
blocked. Replace the specified power supply.
FQPSPCA0065M
Explanation: Message: Power supply %x is too hot.
Note: %x indicates the power supply number. To
determine the power supply number, view details for
the serviceable event that sent you here.
Severity: Critical
Serviceable: Yes
Call Home Candidate: No
Affected Subsystem: Cooling
Event type: Environmental
Response: Ensure the air inlets and outlets of the
system are not blocked. Ensure the power supply fan is
functional. Check for system fan alerts and resolve
those.
FQPSPCA0066M
Explanation: Message: GPU %x suffered an
over-temperature fault. Note: %x indicates the GPU
number. To determine the GPU number, view details
for the serviceable event that sent you here.
Severity: Critical