Clean Detachable Parts And Accessories; Annual/Periodic System Inspection - Frymaster MARINE E4 FPRE 17 kW Installation, Operation, Service, And Parts Manual

Table of Contents

Advertisement

Remove all drops of water from the frypot before filling with oil or shortening.
Failure to do so will cause spattering of hot liquid when the oil or shortening is
heated to cooking temperature.
5.1.4 Clean Detachable Parts and Accessories – Weekly
Wipe all detachable parts and accessories with a clean, dry cloth. Use a clean cloth saturated with
detergent to remove accumulated carbonized oil on detachable parts and accessories. Rinse the parts
and accessories thoroughly with clean water and wipe dry before reinstalling.
5.2

Annual/Periodic System Inspection

This appliance should be inspected and adjusted periodically by qualified service personnel as
part of the galley material maintenance management (3M) program.
Frymaster recommends that a Factory Authorized Servicer inspect this appliance at least
annually as follows:
Fryer
• Inspect the cabinet inside and out, front and rear for excessive oil.
• Verify that the heating element wires are in good condition and that leads have no visible fraying
or insulation damage and that they are free of oil.
• Verify that heating elements are in good condition with no carbon/caramelized oil build-up.
Inspect the elements for signs of extensive dry-firing.
• Verify that the tilt mechanism is working properly when lifting and lowering elements and that
the element wires are not binding and/or chafing.
• Verify the heating-element amp-draw is within the allowed range as indicated on the appliance's
rating plate.
• Verify that the temperature and high-limit probes are properly connected, tightened and
functioning properly, and that mounting hardware and probe guards are present and properly
installed.
• Verify that component box and contactor box components (i.e. controller, relays, interface
boards, transformers, contactors, etc.) are in good condition and free from oil and other debris.
• Verify that component box and contactor box wiring connections are tight and that wiring is in
good condition.
• Verify that all safety features (i.e. contactor shields, drain safety switches, hood shunts, reset
switches, etc.) are present and functioning properly.
DANGER