Appendix D: The Adaptec Hostraid Setup Guidelines - Supermicro X7DBX-8 User Manual

Supermicro x7dbx-8 motherboards: user guide
Table of Contents

Advertisement

The Adaptec HostRAID Setup Guidelines
After all the hardware has been installed, you must fi rst confi gure the Adaptec
Embedded Serial ATA RAID before you install the Windows operating system.
The necessary drivers are all included on the Supermicro bootable CDs that came
packaged with your motherboard. *Note: The following section provides information
on the Adaptec SATA RAID Driver based on the Intel Enterprise South Bridge 2
(ESB2) Controller.
D-1 Introduction to the Adaptec Embedded Serial ATA RAID
Controller Driver
Serial ATA (SATA)
Serial ATA(SATA) is a physical storage interface. It uses a single cable with a
minimum of four wires to create a point-to-point connection between devices. It
is a serial link which supports SATA Transfer rates up to 3.0 Gbps. Because the
serial cables used in SATA are thinner than the traditional cables used in Parallel
ATA(PATA), SATA systems have better airfl ow and can be installed in smaller
chassis than Parallel ATA. In addition, the cables used in PATA can only extend
to 40cm long, while Serial ATA cables can extend up to one meter. Overall, Serial
ATA provides better functionality than Parallel ATA.
Introduction to the Intel ESB2 I/O Controller Hub
Located in the South Bridge of the Intel 5000P Chipset, the ESB2 I/O Controller
Hub provides the I/O subsystem with access to the rest of the system. It supports
1-channel Ultra ATA/100 Bus Master IDE controller (PATA) and one Adaptec's Se-
rial ATA (SATA) Host Controller, which support up to six Serial ATA drives, up to
two RAID volumes and up to four drives in RAID Confi gurations. (See the table
below for details.)
* Adaptec's SATA HostRAID Controller Firmware supports:
Drives supported
Number of RAID Volumes supported
Total Drives in RAID Configurations
Examples of Valid RAID Configurations:
Two drives of RAID 1 + two drives of RAID 0
Two drives of RAID 1 + two drives of RAID 1
Three drives of RAID 0
Four drives of RAID 0
Examples of Invalid RAID Configurations:
Three drives of RAID 0 + two drives of RAID 1
(*Note: this table is applicable to Adaptec's HostRAID Controller
Firmware only.)

Appendix D: The Adaptec HostRAID Setup Guidelines

Appendix D
Six
Two
Four
D-1

Advertisement

Table of Contents
loading

This manual is also suitable for:

X7dbx-i

Table of Contents