Installation - Graco 248824 Instructions And Parts

Feed and solvent flush kits
Table of Contents

Advertisement

Installation

Installation
If this equipment is used in a Hydra-Cat
Mix
proportioning package, see manual 310794.
1.
Install solvent flush kit
a.
See F
IG
bracket (202) and hardware supplied.
Mount bracket on wall, back of propor-
tioner stand, or cart.
For wall mount, ensure that wall is strong enough to
support weight of equipment, fluid, hoses, and
stress caused during operation. Mount at a conve-
nient height for operation and maintenance, and so
suction hose is not stretched tight. Ensure that
equipment is level.
b.
Connect suction hose (207) to elbow
(206) at pump inlet. Place suction tube
in container of solvent.
206
F
. 1: Solvent Flush Kit
IG
6
or Xtreme
. 1. Install pump using mounting
202
207
2.
Install feed kits
a.
b.
c.
102
F
. 2: Feed Pump
IG
TI5675
See F
. 2. Install feed pump (101) in
IG
drum and secure with bung adapter
(BA).
Install air control kit (104).
Screw swivel union (103) into pump fluid
outlet. Connect hose (102) to swivel.
Connect other end of hose to propor-
tioner.
101
103
104
BA
TI5674
310863M