Graco 248824 Instructions And Parts page 7

Feed and solvent flush kits
Table of Contents

Advertisement

3.
Install agitator kit
a.
See F
IG
b.
Screw air line fitting (2a) into agitator
inlet. Connect air line coupler (2b) into
fitting (2a).
2b
F
. 3: Agitator Kit
IG
4.
Connect air lines
a.
Shut off air valves at feed pumps.
b.
Connect air lines to quick disconnect fit-
tings at feed pump and agitator.
310863M
. 3. Install agitator (1) in drum.
2a
1
TI5514
5.
Grounding
WARNING
Your system must be grounded. Read warnings, page
4.
Proportioner pump: follow instructions in propor-
tioner operation manual.
Air and fluid hoses: use only electrically conduc-
tive hoses.
Air compressor: follow manufacturer's recommen-
dations.
Spray gun: ground through connection to a prop-
erly grounded fluid hose and pump.
Feed pumps and solvent pump: follow instruc-
tions in feed pump manual.
Object being sprayed: follow local code.
Solvent pails used when flushing: follow local
code. Use only conductive metal pails, placed on a
grounded surface. Do not place the pail on a non-
conductive surface, such as paper or cardboard,
which interrupts grounding continuity.
To maintain grounding continuity when flushing
or relieving pressure: hold metal part of the spray
gun/dispense valve firmly to the side of a grounded
metal pail, then trigger the gun/valve.
6.
Flush Before Using
Equipment
The equipment was tested with lightweight oil, which is
left in the fluid passages to protect parts. To avoid con-
taminating your fluid with oil, flush the equipment with a
compatible solvent before using the equipment. See
Flushing the System in the proportioner operation
manual.
Installation