CAUTION
Before performing any maintenance
procedures, be sure to READ the lamp,
balloon, and general safety guidelines
in this manual. Failure to read and
understand these safety guidelines could
cause severe equipment damage and
bodily harm.
REMOVING THE LAMP ASSEMBLY
1.
Allow lamp (Figure 17) 15-20 minutes to cool before
changing.
Figure 17.
2.
If lamp assembly is attached to offset pole, loosen
T-handle knob (Figure 18) that secures the lamp to the
offset pole.
T-HANDLE
KNOB
Figure 18.
3.
Lift lamp assebly from offset pole, and place on a
suitable work bench that is free of dirt, and sharp
objects that could damage the balloon.
GB114BS/BP GLOBUG LIGHTING SYSTEM • OPERATION AND PARTS MANUAL — REV. #3 (01/06/09) — PAGE 21
Hot Lamp Surface
LAMP
ASSEMBLY
T-Handle Knob
CAUTION
DO NOT use excessive force when zipping
or unzipping the balloon. The possibility
exists of the zipper tearing, which would
make the balloon unusable.
REMOVING THE BALLOON
1.
Expose the balloon (Figure 19) by pulling down on the
velcro tabs and unzip the protective cover as shown in
Figure 7. Next, fold the protective cover into itself and
zip
ZIPPER
BALLOON
(BOTTOM)
Exposing the Balloon
Figure 19.
2.
Unzip the zipper (Figure 19) at the bottom of the balloon
and roll the balloon envelope upwards to expose the
lamp (Figure 20). Remove the lamp guard to gain
access to the lamp. DO NOT use excessive force when
unzipping the balloon.
LAMP GUARD
PIPE FRAME
Removing the Lamp Guard
Figure 20.

MAINTENANCE

ZIPPER
(TOP)
DO NOT USE
EXCESSIVE FORCE
WHEN ZIPPING OR
UN ZIPPING THE
BALLOON
PROTECTIVE
COVER
(FOLDED)
BALLOON
TO REMOVE
LAMP GUARD
LIFT UPWARDS
FROM PIPE FRAME