Trane GAM5B0A18M11EB Installation, Operation And Maintenance Manual page 36

Convertible air handlers
Table of Contents

Advertisement

EXTERNAL STATIC
(in w.g)
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
NOTES:
1. Values are with wet coil and without filters.
2. Contact your particular filter manufacturer for pressure drop data.
3. Electric heater pressure drop is negligible and is included within the airflow data.
4. Tap 1 is an continuous fan speed tap for single stage systems. Airflow adjustment is required for 2 stage systems.
See Airflow adjustment section.
5. † Factory Setting
GAM5B0B36M31SB, GAM5B0B36M31EA MINIMUM HEATER AIRFLOW CFM
Heater
BAYEAAC04BK1
BAYEAAC04LG1
BAYEAAC05BK1
BAYEAAC05LG1
BAYEAAC08BK1
BAYEAAC08LG1
BAYEAAC10BK1
BAYEAAC10LG1
BAYEAAC10LG3
BAYEABC15BK1
BAYEABC15LG3
BAYEABC20BK1
BAYEACC25BK1
Note: Heating and cooling speeds are the same, factory
set at Speed Tap #4.
Note: A "G" only signal from the comfort control will run
the blower at a lower speed, factory set at Speed Tap #1.
See the Sequence of Operation for additional information.
Note: Speed Tap 1 is NOT used for two stage systems.
Two stage systems will require an airflow adjustment.
36
AIRFLOW PERFORMANCE
GAM5B0B36M31EB
Speed Taps - 230 VOLTS
5
4 †
3
1438
1387
1197
1394
1340
1143
1350
1299
1090
1301
1245
1031
1253
1197
975
1205
1151
917
1155
1094
837
1099
1032
766
1039
972
691
964
889
633
Minimum Air Speed Tap
Without HP
Tap 2
Tap 2
Tap 3
Tap 4
Tap 4
Tap 4
Tap 4
-
-
AIRFLOW (CFM)
2
1
5
1013
732
1435
945
552
1388
892
413
1341
817
305
1289
751
209
1239
651
-
1188
578
-
1136
499
-
1077
453
-
1014
409
-
936
With HP
Tap 3
Tap 3
Tap 4
Tap 5
Tap 5
Tap 5
Tap 5
-
-
Speed Taps - 208 VOLTS
4 †
3
2
1383
1194
1009
1334
1137
939
1291
1082
884
1233
1019
806
1183
960
737
1134
900
634
1075
817
559
1010
744
476
946
666
-
861
605
-
1
729
546
404
293
195
-
-
-
-
-