Trane GAM5B0A18M11EB Installation, Operation And Maintenance Manual page 35

Convertible air handlers
Table of Contents

Advertisement

EXTERNAL STATIC
(in w.g)
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
NOTES:
1. Values are with wet coil and without filters.
2. Contact your particular filter manufacturer for pressure drop data.
3. Electric heater pressure drop is negligible and is included within the airflow data.
4. Tap 1 is an continuous fan speed tap for single stage systems. Airflow adjustment is required for 2 stage systems.
See Airflow adjustment section.
5. † Factory Setting
GAM5B0A24M21SB, GAM5B0A24M21EA MINIMUM HEATER AIRFLOW CFM
Heater
BAYEAAC04BK1
BAYEAAC04LG1
BAYEAAC05BK1
BAYEAAC05LG1
BAYEAAC08BK1
BAYEAAC08LG1
BAYEAAC10BK1
BAYEAAC10LG1
BAYEAAC10LG3
BAYEABC15BK1
BAYEABC20BK1
① Heater not qualified for downflow installations
② Approved for 240 V only
Note: Heating and cooling speeds are the same, factory
set at Speed Tap #4.
Note: A "G" only signal from the comfort control will run the
blower at a lower speed, factory set at Speed Tap #1. See
the Sequence of Operation for additional information.
Note: Speed Tap 1 is NOT used for two stage systems.
Two stage systems will require an airflow adjustment.
AIRFLOW PERFORMANCE
GAM5B0A24M21EB
Speed Taps - 230 VOLTS
5
4 †
3
1081
977
937
1044
922
868
995
880
817
956
830
767
914
788
719
872
749
680
838
707
628
802
650
566
755
598
511
708
539
460
Minimum Air Speed Tap
Without HP
Tap 3
Tap 3
Tap 3
Tap 3 ①
Tap 5
-
-
AIRFLOW (CFM)
2
1
5
928
579
1078
844
418
1038
777
306
987
729
-
944
682
-
900
635
-
855
577
-
819
515
-
779
467
-
730
407
-
680
With HP
Tap 4
Tap 4
Tap 4
Tap 5 ①
Tap 5 ②
-
-
Speed Taps - 208 VOLTS
4 †
3
2
974
933
925
916
863
838
871
808
768
819
756
717
774
705
668
732
663
618
687
609
557
628
544
492
573
486
442
512
432
-
1
576
412
298
-
-
-
-
-
-
-
35