Section 1. Safety Information - Trane GAM5B0A18M11EB Installation, Operation And Maintenance Manual

Convertible air handlers
Table of Contents

Advertisement

Section 1. Safety Information

!
WARNING
SAFETY HAZARD!
This information is intended for
use by individuals possessing adequate backgrounds
of electrical and mechanical experience. Any attempt to
repair a central air conditioning product may result in
personal injury and/or property damage. The manufac-
turer or seller cannot be responsible for the interpreta-
tion of this information, nor can it assume any liability
in connection with its use.
!
WARNING
LIVE ELECTRICAL COMPONENTS!
stallation, testing, servicing, and troubleshooting of this
product, it may be necessary to work with live electrical
components. Failure to follow all electrical safety pre-
cautions when exposed to live electrical components
could result in death or serious injury.
!
HAZARDOUS VAPORS!
handler with a non-ducted return in the same closet,
alcove, or utility room as a fossil fuel device. Hazardous
vapors can be distributed throughout the conditioned
space and equipment damage can result.
!
WARNING
This product can expose you to chemicals including
lead, which are known to the State of California to case
cancer and birth defects or other reproductive harm.
For more information go to www. P65Warnings.ca.gov
Important: Panel damage can occur with prolonged
exposure to POE lubricants. Air handler front panels
that come in contact with POE oil must be washed
immediately with soapy water.
Important: Can not leave door panels in the sun during
installation as the extreme temperature has a tendency
to warp the plastic outer panel.
During in-
CAUTION
Do not install an air
!
CORROSION HAZARD!
service life, the air handler should not be used during
the finishing phases of construction. The low return air
temperatures can lead to the formation of condensate.
Condensate in the presence of chlorides and fluorides
from paint, varnish, stains, adhesives, cleaning
compounds, and cement creates a corrosive condition
which may cause rapid deterioration of the cabinet and
internal components.
!
SAFETY HAZARD!
Sharp Edge Hazard. Be careful
of sharp edges on equipment or any cuts made on
sheet metal while installing or servicing. Personal injury
may result.
!
WARNING
PRESSURIZED REFRIGERANT!
CONTAINS OIL AND REFRIGERANT UNDER HIGH
PRESSURE. RECOVER REFRIGERANT TO RELIEVE
PRESSURE BEFORE OPENING THE SYSTEM.
DO NOT USE NON-APPROVED REFRIGERANTS OR
REFRIGERANT SUBSTITUTES OR REFRIGERANT
ADDITIVES.
Note: This unit is certified to UL 1995.
The interior cabinet wall meets the following:
- UL94-5VA Flame Class Listed
- UL723 Steiner Tunnel Listed for 25/50 Flame/
Smoke
- UL746C Listed for Exposure to Ultraviolet Light,
Water Exposure and Immersion
CAUTION
To prevent shortening its
CAUTION
SYSTEM
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents