BEFORE PERFORMING ANY
ELECTRICAL WORK, READ
THESE REGULATIONS
1. All wiring must comply with local and
national electrical codes, regulations and
must be installed by a licensed
electrician.
2. All electrical connections must be
made according to the Electrical
Connection Diagram located on the
panels of the indoor and outdoor units.
3. If there is a serious safety issue with
the power supply, stop work
immediately. Explain your reasoning to
the client, and refuse to install the unit
until the safety issue is properly
resolved.
4. Power voltage should be within 90-
110% of rated voltage. Insufficient power
supply can cause malfunction, electrical
shock, or fire.
5. If connecting power to fixed wiring, a
surge protector and main power switch
should be installed.
6. If connecting power to fixed wiring, a
switch or circuit breaker that disconnects
all poles and has a contact separation of
at least 1/8in (3mm) must be
incorporated in the fixed wiring. The
qualified technician must use an
approved circuit breaker or switch.
7. Only connect the unit to an individual
branch circuit outlet. Do not connect
another appliance to that outlet.
8. Make sure to properly ground the air
conditioner.
9. Every wire must be firmly connected.
Loose wiring can cause the terminal to
overheat, resulting in product
malfunction and possible fire.
10. Do not let wires touch or rest against
refrigerant tubing, the compressor, or
any moving parts within the unit.
11. If the unit has an auxiliary electric
heater, it must be installed at least 1
meter (40in) away from any combustible
materials.
12. To avoid getting an electric shock,
never touch the electrical components
soon after the power supply has been
turned off. After turning off the power,
always wait 10 minutes or more before
you touch the electrical components.
WARNING
BEFORE PERFORMING ANY
ELECTRICAL
TURN OFF THE MAIN POWER TO
THE SYSTEM.
Connect signal and power cables
The signal cable enables communication
between the indoor and outdoor units.
You must first choose the right cable
size before preparing it for connection.
Cable Types
• Indoor Power Cable (if applicable):
H05VV-F or H05V2V2-F
• Outdoor Power Cable: H07RN-F or
H05RN-F
• Signal Cable: H07RN-F
NOTE: In North America, choose the
cable type according to the local
electrical codes and regulations.
Minimum Cross-Sectional Area of
Power and Signal Cables (For
reference) (Not applicable for North
America)
Rated Current of
Appliance (A)
> 3 and ≤ 6
>6 and ≤ 10
>10 and ≤ 16
>16 and ≤ 25
>25 and ≤ 32
>32 and ≤ 40
17
-
VIVAX
OR WIRING WORK,
Nominal Cross-
Sectional Area
2
(mm
)
0.75
1
1.5
2.5
4
6