INSTALLING YOUR APPLIANCE (CONTINUED)
Cabinet construction for your appliance
For the best integration within a kitchen, install the
appliance in a standard 600mm wide cupboard that gives
a flush fit with the surrounding cupboard fronts as shown
in Fig. A. A recess of 20 mm is ideal.
With the exception of pyrolytic ovens, the appliance can
also be installed using a proud fit to the surrounding
cupboard as shown in Fig. B.
WARNING
CAUTION
The "Infill panel" MUST not exceed 100mm in length. This
ensures a 16mm gap is maintained between the cabinet
and oven side to prevent the cupboard overheating.
Fig. A
Flush Fit
Cupboard
door
Fig. B
Proud Fit
Cupboard
door
Levelling oven
Place a level in the oven as below, making sure the level
sits on the front and rear forms.
6
INSTALLING YOUR APPLIANCE
16mm
568mm
Infill
panel
100mm max
for Pyro
oven
20mm
Oven
600mm
16mm
568mm
Infill
panel
100mm max
for Pyro oven
Oven
600mm
Pyrolytic underbench oven
Your underbench oven looks best when the control panel
is directly under the benchtop. An upper infill panel may
have to be added if the cooktop placed over the oven is
too deep. Refer to cooktop installation instructions for
required clearance between cooktop and oven.
Power point connection for the WVEP6918 must be
accessible with the appliance fully installed. If the supply
cord is damaged it must be replaced by the manufacturer,
its service agent or similarly qualified persons in order to
avoid
a hazard.
WARNING
CAUTION
NOTE: Dimension "D".
A requirement for all pyrolytic clean ovens – for proper
ventilation there must be a gap at the bottom rear of the
cabinet. This can be a full width opening 20mm deep.
upper infill
(if required)
A
B
D
C
GAS TYPE
A
Flush fit
600
Proud fit
565
558
use black
installation
596
screws supplied
B
C
600
581min
590
560min
mounting
holes
D
20
20