C83
Air inlet
Air inlet
C93
48
Closed
Air supply
Flue outlet
from outside
Closed
Air supply
from outside
E93.1804.014
* Separate air supply duct from external wall.
*Flue gas discharge through individual or shared
flue ducting built into the building.
* Air supply inlet and flue gas outlet at different air
pressure zones.
* Condensate is not allowed to go to the boiler.
* Technical data:
nominal T
flue gas
nominal Q
fluegas
maximum T
fluegas
min. load T
fluegas
min. load Q
fluegas
nominal % O
2
1) technical specifications datasheet
* Flue duct: Material: PP or SS
CE approved
Type C93 . A type C9 appliance incorporating a
fan upstream of the combustion chamber/heat-
exchanger.
Minimum required diameter/ cross section area:
boiler
diameter
EFW 85, 105, 125
100 mm
EFW 155
150 mm
85 °C
see 3.3
1)
90 °C
35 °C
1)
see 3.3
1)
see 3.3
area
2
7854 mm
2
17671 mm