Electrical Data; Three Phase Burner - Riello RLS 130/E Installation, Use And Maintenance Instructions

Dual fuel light oil/gas burner
Table of Contents

Advertisement

3.3

Electrical data

3.3.1

Three phase burner

Fan motor and pump motor IE1
Model
RBNA Code
Control circuit power supply
Main electrical supply (+/- 10%)
Fan motor
Pump motor
Ignition transformer
Electrical power consumption
Electrical control circuit coms.
Total electrical consumption
Electrical protection
Fan motor and pump motor IE2/EPACT
Model
RBNA Code
Control circuit power supply
Main electrical supply (+/- 10%)
Fan motor
Pump motor
Ignition transformer
Electrical power consumption
Electrical control circuit coms.
Total electrical consumption
Electrical protection
Technical description of the burner
V/Ph/Hz
V/Ph/Hz
rpm
HP
V
A
rpm
HP
V
A
Oil
V1 - V2
I1 - I2
Gas
V1 - V2
I1 - I2
W max
W
W
V/Ph/Hz
V/Ph/Hz
rpm
HP
V
A
rpm
HP
V
A
Oil
V1 - V2
I1 - I2
Gas
V1 - V2
I1 - I2
W max
W
W
C9336400
208-220/3/60
3400
3
208 - 230
8.5
3440
1
208 - 230
3.2
3750
4500
C9336400
208-220/3/60
3500
3
208 - 230
7.8
3520
1
208 - 230
3.2
7
GB
RLS 130/E
C9336410
C9336401
120/1/60
460/3/60
575/3/60
3400
3
460
4.9
3440
1
460
1.7
120 V - 2 x 5 kV
2.7 A - 30 mA
120 V - 1 x 8 kV
1.6 A - 20 mA
4250
750
5000
NEMA 1
RLS 130/E
C9336410
C9336401
120/1/60
460/3/60
575/3/60
3500
3
460
3.9
3520
1
460
1.6
120 V - 2 x 5 kV
2.7 A - 30 mA
120 V - 1 x 8 kV
1.6 A - 20 mA
3550
750
4300
NEMA 1
3400
3
575
3.7
3440
1
575
1.4
4100
4850
Tab. C
3500
3
575
3.1
3520
1
575
1.3
Tab. D
20031446

Advertisement

Table of Contents
loading

This manual is also suitable for:

C9336400C9336410C9336401

Table of Contents