Technical Description Of The Burner; Technical Data; Burner Models Designation - Riello RLS 130/E Installation, Use And Maintenance Instructions

Dual fuel light oil/gas burner
Table of Contents

Advertisement

3

Technical description of the burner

3.1

Technical data

Model
Output
(1)
Delivery
(1)
Fuel
Gas pressure at maximum delivery
Gas: Natural gas
Operation
Nozzle
Standard applications
Ambient temperature
Combustion air temperature
Pump
delivery (at 174 PSI)
pressure range
fuel temperature
Noise levels
(3)
Reference conditions: Ambient temperature 68 °F (20°C) - Barometric pressure 394" WC - Altitude 329 ft.
(1)
Pressure at test point 18)(Fig. 1) with zero pressure in the combustion chamber and maximum burner output.
(2)
Sound pressure measured in manufacturer's combustion laboratory, with burner operating on test boiler and at maximum rated output.
(3)
Equivalent Btu values based on 1 USGPH = 140,000 Btu/hr.
(4)
3.2

Burner models designation

Model
Code
RLS 130/E
20030386
20031446
Technical description of the burner
High
MBtu/hr
(4)
kW
GPH
Low
MBtu/hr
(4)
kW
GPH
" WC
(2)
number
°F
°F max
GPH
PSI
° F max
dB(A)
Code RBNA
C9336400
C9336410
C9336401
Modulating oil/gas
Boilers: water, steam, thermal oil
32 - 104 (0 - 40 °C)
Voltage
Flame safeguard
208-220/3/60
460/3/60
Burner mounted
575/3/60
6
GB
RLS 130/E
3500 - 5292
1026 - 1551
25 - 37.8
1750
513
12.5
#2 Fuel oil
Natural gas
1.04
1
140 (60 °C)
60.8
145 - 304.5
194 (90 °C)
80
Tab. A
Tab. B

Advertisement

Table of Contents
loading

This manual is also suitable for:

C9336400C9336410C9336401

Table of Contents