• Wait until the power tool has stopped
before placing it down. The attachment
tools can jam and lead to a loss of con-
trol over the power tool.

Residual risks

Even if properly operating and handling
this electric tool, some residual risks will
remain. Due to its construction and build,
this electric tool may present the following
hazards:
a) Cuts
b) Ear damage if working without ear pro-
tection.
c) Damage to your health caused by
swinging your hands and arms when
operating the appliance for longer pe-
riods of time or if the unit is not held or
maintained properly.
Warning! During operation, this
electric tool generates an electro-
magnetic fi eld which, under certain
circumstances, may impair the func-
tionality of active or passive medical
implants. To reduce the risk of seri-
ous or lethal injuries, we recommend
that persons with medical implants
consult their doctor and the manu-
facturer of their medical implant
before operating the machine.

Assembly

Only insert the battery once
the battery-operated tool is
fully ready for use.
Attaching/removing the
protective cover
Attaching the protective cover
1. Press the two holders on the protective
cover (15) into the recesses on the ap-
pliance housing. The protective cover
(15) locks into place.
You can fold the fi tted protective
cover (15) up by 90°.
Removing the protective cover
2. Carefully press the two holders on the
protective cover (15) apart.
3. Pull the protective cover (15) to the
front.
Assembling/removing
the slide shoe
When working on scratch-sensitive work-
pieces, working with the slide shoe (20) is
recommended.
Attaching the slide shoe
1. Place the shoe (20) on the front of the
bottom plate (5).
2. Now, press the notches (20a) on the
back of the slide shoe over the base-
plate (5).
Removing the slide shoe
1. Press the slide shoe (20) on the notches
(20a) from the baseplate (5).
2. Pull the slide shoe (20) forward, away
from the baseplate (5).
Removing/inserting the
rechargeable battery
1. To remove the battery (22) from the
device, press the release button (23)
on the battery and pull the battery (22)
out.
2. To insert the battery (22), push the bat-
tery (22) along the guide rail into the
device. You will hear it click into place.
GB