Siemens SIMATIC NET RUGGEDCOM RST2428P Equipment Manual page 55

Rugged ethernet switches
Table of Contents

Advertisement

Installing the device
2.5.5 Grounding the device
The functional ground must be implemented with low impedance. The connection of
the functional ground must be established directly on the mounting plate or the DIN
rail terminal.
Requirements
Note
Protective grounding during operation in compliance with UL 62368-1/CSA-
C22.2 No. 62368-1
When operating in compliance with UL 62368-1/CSA-C22.2 No. 62368-1, the device
must be connected to protective grounding via the grounding screw to meet UL
approval requirements. The work must be performed by a qualified electrician in
accordance with UL 62368-1/CSA-C22.2 No. 62368-1.
To wire a permanently connected protective grounding, use #14-8 AWG copper
cables or copper cables with a cross-section of 1.5 to 6 mm
Required tools/hardware
#1 Phillips screwdriver
Braided or equivalent ground wire
M3.5 (#6) ring tongue
Attaching the ground connection
To permanently attach a ground connection to the device, do the following:
1.
46
Hardware
Remove the M3 screw
1
2
M3 screw
1
Quantity
1
1
1
.
1
2
(0.05 to 0.2 in
Detail
For removing/installing terminal blocks
and the terminal block cover.
For grounding the device to safety
Earth.
For connecting the ground wire to the
chassis ground connection.
RUGGEDCOM RST2428P
Equipment Manual, 10/2023, C79000-G8976-1528-01