Firmware and configuration data are stored in a secured memory area on the CLP,
which can only be accessed via the device.
Position
The CLP slot is located below the status panel.
Figure 1.6
Function
In the startup phase:
During operation:
Insertion and removal
For information about how to insert or remove the CLP, refer to "Inserting/removing
the CLP" (Page 58).
Operating hazard – risk of data loss
Only insert or remove the CLP when the device is de-energized.
RUGGEDCOM RST2428P
Equipment Manual, 10/2023, C79000-G8976-1528-01
Configuration License PLUG (CLP)
When a CLP with no data (default setting) is plugged into a device, the device
automatically saves its configuration data on the CLP.
If a CLP with data is plugged into a device, the device automatically adopts the
configuration installed on the CLP.
Changes to the configuration are saved on the CLP and in the internal memory.
The device checks every second if a CLP is inserted. If the device detects the CLP
has been removed, it restarts automatically.
Errors detected in the CLP data and/or file system (e.g. incompatible data,
incorrect operation, or malfunctions) are communicated to users via SINEC OS.
NOTICE
1.2.4 Configuration and License PLUG (CLP)
Introduction
11