Bradford White Magnum D75T125E3N Installation & Operation Manual page 43

Gas-fired commercial water heater
Table of Contents

Advertisement

To Display and Change Temperature Setpoint:
Step 1: In "Service Mode" press the "Select" button until "Setpoint" is shown in the water heater display.
Step 2: Press the "Set" button to enter the setting mode. "Setpoint" will flash in the water heater display.
Step 3: To raise the temperature setpoint, press the "Temperature Up" button until the desired temperature is shown on the
water heater display.
Note: The maximum temperature that can be set in the Water Heater Display is limited to the "Max Setpoint"
described previously. To change the "Max Setpoint", refer to the procedure "To Change the Maximum Setpoint
Limit..." described previously under "Accessing the Service Mode on the Water Heater Display".
idle
Operational
Status
SELECT
idle
Operational
Status
SELECT
NOTICE
idle
Operational
Status
SELECT
setpoint
°F
SET
"Setpoint" Flashes
setpoint
°F
SET
"Setpoint" Flashes
setpoint
°F
SET
43