6.3.3 To remove the pipe port cover
6.4 Connecting the drain piping
In this chapter
6.4.1 General guidelines
CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S)
Daikin room air conditioner
4P518023-15P – 2023.05
INFORMATION
To connect the piping on right-side, right-bottom, left-side or left-bottom, the pipe
port cover MUST be removed.
1 Cut off the pipe port cover from inside the front grille using a coping saw.
2 Remove any burrs along the cut section using a half round needle file.
NOTICE
Do NOT use nippers to remove the pipe port cover, as this would damage the front
grille.
6.4.1
General guidelines..................................................................................................................................................
6.4.2
To connect the piping on right side, right-back, or right-bottom.........................................................................
6.4.3
To connect the piping on left side, left-back, or left-bottom................................................................................
6.4.4
To check for water leaks ........................................................................................................................................
▪
Pipe length. Keep drain piping as short as possible.
▪
Pipe size. If drain hose extension or embedded drain piping is required, use
appropriate parts that match the hose front end.
NOTICE
▪
Install the drain hose with a downward slope.
▪
Traps are NOT permitted.
▪
Do NOT put the end of the hose in water.
6
Unit installation
|
29
30
31
32
Installer reference guide
29