6.3 Mounting the indoor unit

In this chapter

6.3.1 To install the mounting plate

CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S)
Daikin room air conditioner
4P518023-15P – 2023.05
a
b
a Screw
b Electrical wiring box
c Rear hook
4 To re-install the cover, first attach the electrical wiring box to the hooks, close
the electrical wiring box, and re-install the screw.
NOTICE
When closing the electrical wiring box cover, make sure that the tightening torque
does NOT exceed 2.0 (±0.2) N•m.
6.3.1

To install the mounting plate.................................................................................................................................

6.3.2
To drill a wall hole ..................................................................................................................................................
6.3.3
To remove the pipe port cover ..............................................................................................................................
1 Install the mounting plate temporarily.
2 Level the mounting plate.
3 Mark the centres of the drilling points on the wall using a tape measure.
Position the end of tape measure at symbol " ".
4 Finish the installation by securing the mounting plate on the wall using
M4×25L screws (field supply).
INFORMATION
The removed pipe port cover can be kept in the mounting plate pocket.
6
Unit installation
|
c
c
Installer reference guide