Configuration; To Set A Different Channel Of The Indoor Unit Infrared Signal Receiver - Daikin FTXA20C2V1BW Installer's Reference Manual

Hide thumbs Also See for FTXA20C2V1BW:
Table of Contents

Advertisement

10 Configuration

10.1 To set a different channel of the indoor unit infrared signal receiver

CTXA-C(W)(B)(S) + FTXA-C(W)(B)(S)
Daikin room air conditioner
4P518023-15P – 2023.05
In case 2 indoor units are installed in 1 room, different addresses for 2 user
interfaces can be set.
1 Remove the cover and the batteries from the user interface.
2 Cut the address jumper J4.
a Address jumper J4
NOTICE
Be careful NOT to damage any of the surrounding parts when cutting the address
jumper.
3 Turn the power supply on.
4 Press
and
5 Press
, select and press
Result: The operation lamp will start to blink.
a Indoor unit ON/OFF switch and operation lamp
6 Press the indoor unit ON/OFF switch while the operation lamp is blinking.
Address jumper
Factory setting
After cutting with nippers
INFORMATION
If the setting could NOT be completed while the operation lamp was blinking, repeat
the setting process from the beginning.
simultaneously.
.
a
Address
1
2
10
Configuration
|
a
Installer reference guide
47

Advertisement

Table of Contents
loading

Table of Contents