102
a
e d
a
50
180
a
Recommended mounting plate fixing spots
b
Pocket for the pipe port cover
c
Tabs for placing a spirit level
d
Through-the-wall hole Ø65 mm
e
Drain hose position
5.2.2

To drill a wall hole

CAUTION
For walls containing a metal frame or a metal board, use a
wall embedded pipe and wall cover in the feed-through
hole to prevent possible heat, electrical shock, or fire.
NOTICE
Be sure to seal the gaps around the pipes with sealing
material (field supply), in order to prevent water leakage.
1 Bore a 65  mm large feed-through hole in the wall with a
downward slope towards the outside.
2 Insert a wall embedded pipe into the hole.
3 Insert a wall cover into the wall pipe.
a b
c
a
Wall embedded pipe
b
Putty
c
Wall hole cover
CTXM-A, FTXM-A, ATXM-A
Daikin room air conditioner
3P697375-8B – 2023.06
b
c
a
46
f1
a
h
g
96
361
802
INFORMATION
The removed pipe port cover can be kept in the mounting
plate pocket.
252
c
a
f2
341
f1
Measure point for piping hole center " " (to left)
f2
Measure point for piping hole center " " (to right)
g
Gas pipe end
h
Liquid pipe end
4 After completing wiring, refrigerant piping and drain piping, do
NOT forget to seal the gap with putty.
5.2.3

To remove the pipe port cover

INFORMATION
To connect the piping on right-side, right-bottom, left-side
or left-bottom, the pipe port cover MUST be removed.
1 Cut off the pipe port cover from inside the front grille using a
coping saw.
2 Remove any burrs along the cut section using a half round
needle file.
5 Unit installation
100
a
a
d
e
150
50
(mm)