Accuracy is specified as ±( [% of reading] + [number of least significant digits] ). All ranges are autoranging. Accuracy is
specified from 1 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C.

AC Voltage

Range
6.000 V
60.00 V
600.0 V
1000 V
[1]
Crest factor of ≤3 at full scale to a maximum of 4000 counts, decreasing linearly to crest factor ≤1.5 at full scale.
[2]
For non-sinusoidal waveforms, add -(2 % of reading + 2 % full scale) typical, for crest factor to a maximum of 3.
[3]
Do not exceed 10

General

LCD w/Backlight .................................................... 3 ½ digits, 6000 counts, 4/sec update rate
Log Rate/Interval ................................................... adjustable by PC from 1 second to 1 hour, default is 1 minute
Memory ................................................................. Record up to 65 000 readings
Battery Type .......................................................... 2 AA, NEDA 15 A, IEC LR6
Battery Life ............................................................ 400 hours
Radio Frequency Communications ....................... 2.4 GHz ISM Band
Radio Frequency Communication Range ............. 20 m (66 ft)
Operating Temperature ......................................... -10 °C to +50 °C, (14 °F to 122 °F)
Storage Temperature ............................................ -40 °C to +60 °C, (-40 °F to 140 °F) with batteries removed
Operating Humidity ............................................... 90 % from 0 °C to 35 °C, 45 % to 40 °C, 45 % to 50 °C
Operating Altitude ................................................. 2 000 m (6 561 ft)
Storage Altitude .................................................... 12 000 m (39 370 ft)
Ingress Protection (IP) rating ................................ IP42
Safety .................................................................... IEC 61010-1, Pollution Degree 2
Electromagnetic Compatibility............................... Radio Frequency Emissions, IEC CISPR 11: Group 1, Class A. Group 1
Applies to use in Korea only ........................... Class A Equipment (Industrial Broadcasting & Communication
Electromagnetic Environment ............................... IEC 61326-1: Portable
Temperature Coefficient ....................................... 0.1 X (specified accuracy)/ °C (<18 °C or >28 °C)
Size ....................................................................... 160 mm x 66 mm x 38 mm (6.3 in x 2.6 in x 1.5 in)
Weight ................................................................... 0.255 kg (9 oz)
4
Resolution
0.001 V
0.01 V
0.1 V
1 V
6
V-Hz
(90 % from 32 °F to 95 °F, 45 % to 104 °F, 45 % to 122 °F)
IEC 61010-2-033:Measurement 1000V CAT III/600V CATIV
have intentionally generated and/or use conductively coupled radio-
frequency energy which is necessary for the internal functioning of the
equipment itself.
Class A equipment is suitable for use in non-domestic locations and/or
directly connected to a low-voltage power supply network. Class A
equipment may have potential difficulties in ensuring electromagnetic
compatibility in other environments due to conducted as well as radiated
disturbances.
Equipment)
This product meets requirements for industrial (Class A)
electromagnetic wave equipment and the seller or user should take
notice of it. This equipment is intended for use in business environments
and is not to be used in homes.
[1][2][3]
Accuracy
45 Hz to 500 Hz
1.0 % + 3
500 Hz to 1 kHz
2.0 % + 3

Advertisement