4.3.1 Clocking Configuration
The Clocking tree on this controlCARD is configurable. Both a 20 MHz clock source and a 25 MHz (default)
clock source can be provided to the F28P650DK9 device. To change this configuration, the R75 0-Ω resistor
must be de-soldered and moved to the R70 location.

Figure 4-1. Changing the Clock Source From 25 MHz to 20 MHz

4.4 Experimentation Software

Code Composer Studio (CCS) Integrated Development Environment (IDE)
and debugging software for the C2000 series of MCUs. The CCS IDE is free to download and use with the
controlCARD. Introductory videos for CCS IDE are available at training.ti.com.